Standard Operation
Operating Information
⑥
②
①
① Operation Mode
Select the operation mode to set the desired mode.
Select OFF from the options list to stop operation.
- Details of operation mode
Operation Aircon Ventilation
Cool
O
DX
Heat
O
DX
Auto
O
DX
Dry
O
Fan
O
General
Bypass
DX
Heat
General
Exchange
DX
⑦
⑤
③
④
Explanation
Set the desired temperature
lower than the indoor
temperature. It cools the
room with a pleasant and
fresh wind.
Set the desired temperature
above the indoor
temperature. It provides
warm air for the indoor.
The product automatically
provides a suitable
temperature wind for indoor.
You can dehumidify and
cool at the same time. It
is suitable for use when
humidity is high.
Air that has no temperature
difference compare to indoor
is released to circulate the
indoor air.
Exhausted air is ventilated
not through the total heat
exchanger. It is suitable for
use in seasons with small
indoor/outdoor temperature
differences or when indoor
pollution is severe.
Both supply air and
exhausted air are ventilated
through the total heat
exchanger. It is suitable for
use in seasons with large
indoor/outdoor temperature
differences.
STANDARD OPERATION
Operation Aircon Ventilation
Ventilation
General
Auto
DX
OFF
O
O
Emergency
Heater
O
Air
O
Purify
Power
O
Heat
Power
O
Cool
Himalaya
O
Cool
Monsoon
O
Dry
NOTE
• The reason why the cool air isn't coming out
immediately after cooling is started is because
of its function to protect the compressor. After 3
minutes, the compressor operates, and a cold wind
comes out.
• Heating/automatic operation only works on heating
and cooling models.
• Depending on the outdoor unit cycle operation, the
background color of the home screen is expressed
in red for heater and blue for air conditioner.
• The emergency heater is activated under
emergency heating conditions after the installation
and related settings.
• Depending on the product, some functions cannot
be set.
② Room Temperature
Displays room temperature.
11
Explanation
Sense the indoor and
outdoor temperature and
automatically operate in
optimum ventilation mode.
The product operation is
stopped.
After the emergency
heater is set up for use,
the operation mode can be
selected in the emergency
heating operation condition
using the heater.
The single operation of an
air purifier.
Increases room temperature
quickly.
It quickly lowers the room
temperature.
The local special function
applied to models in the
India region quickly reduces
room temperature.
A local special
dehumidification function
applied to models in India.