Air conditioner Installer setting
Product
Function
Aircon
Test Run
O
Central Control Address
O
ESP
O
Temperature
O
Sensor(2TH)
Ceiling Height Selection
O
Static Pressure
O
Override Master/Slave
O
Dry Contact Mode
O
Fixed Air Volume
O
Zone type
O
Zone Number
O
Pipe Temperature
O
Func. Control During
O
Grp. Control
Function setting during
O
Group control
Option kit installation
- Air purify / Heater
/Humidification
O
/ Elevationgrill /
Ventilation /Refrigerant
leakagedetection sensor
IDU Address Verification
O
Static Pressure Step
O
Guard Timer
O
Fan Speed in Cooling
O
Thermal Off
Description
Vent
It is the function to test the operation at initial
O
installation.
Assign a unique address code of indoor units
O
when used with central controller.
Sets the wind amount value for each fan speed. Select fan speed one by one to set each RPM value.
Select which standard temperature value that
O
will be used to control temperature.
It is the function to change the wind amount
according to the ceiling height for the ceiling
type products.
This function changes the fan speed in the
indoor FAN according to the opening and closing
quantity of Damper.
This function prevents operation of other modes.
Products set as slave can only be changed to
O
the operation mode of the master product.
- Unable to operate cooling and heating at the
same time
This function activates/inactivates the dry
O
contact auto function.
This function sets the fan speed mode of the
O
indoor unit to variable/fixed.
This function sets the type of zone controller
(New or Old) of the indoor unit.
Set the number of installed zones in case of
using new type of zone
You can check the temperature of the pipe
O
temperature.
You can set the emergency heater usage and
environment.
This function selects the operation standard of
the product when controlling the group.
Please set whether to install the option kit.
Check the value of Auto Addressing of the
O
outdoor unit with the remote controller.
This function allows you to set the static
pressure of the duct product by subdividing it
into 11 steps.
The standby time can be set to protect the
outdoor unit during cycle transition of 2 set auto
mode operation.
It is a function that sets the indoor unit fan
O
operation, in cooling mode, when thermal is off.
INSTALLER SETTING
Option
Cool test Run / Heat Test Run
00~FF
Remote controller / Indoor unit / 2TH
Low / Standard / High / Super High
V-H : Indoor fan speed change, High pressure
F-H : Fixed with set fan speed, High pressure
V-L : Indoor fan speed change, Low pressure
F-L : Fixed with the set fan speed, Low pressure
Master / Slave
Automatic / Manual
Variable
Operate to set fan speed
Operate to set fan speed
at COMP ON.
Operate to low fan speed
Operate to set fan speed
at COMP OFF.
at COMP OFF.
Old
New or 8 zone
Only the operation status
Zone control and
of the zone using a wired
monitoring is possible
remote controller can be
using wired remote
checked.
2~8
Use / Not Use
Not installed / Installed
Step 0~ Step 11
If you step settings, static pressure settings is not
used.
• Refer to the indoor unit product manual for the
static pressure values in each step.
Step 0
Step 1
Step 2
0 min
15 min
30 min
Low / Off / Setting value
25
Fixed
at COMP ON.
controller.
Step 3
Step 4
45 min
60 min