Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 35)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
Maintenance (see page 35)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
Dimensions (see page 38)
Flow diagram (see page 39)
Normal spray
Regular
Spare parts (see page 40)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Special accessories (order as an extra)
extension #43333000 (see page 34 / 40)
Cleaning (see page 37)
Operation (see page 36)
• Hansgrohe recommends not to use as drinking water the first half liter of water
drawn in the morning or after a prolonged period of non-use.
Fault
Mixer stiff
Mixer dripping
Water escaping at the threaded base
Hot water temperature too low
Low flow with Select valve after valve replacement
Select button stiff
4
English
• Minor leaking may occur briefly at the spout when opening the fitting via the
• Use the lever to open the tap and set the desired temperature. The water flow
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring at the connection hose defective.
- connection hoses not completely screwed into basic
body
- Hot water limiter incorrectly set
- Improper Select valve installed
- Select button soiled
Assembly (see page 31)
lever.
can be paused by pressing the Select button on the face side of the spout.
When the tap is not used for a longer period of time, f.e. when retiring at night
or leaving the house, it must be closed completely by means of the lever.
Test certificate (see page 40)
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Set hot water limiter
- Replace Select valve (#98463000)
- Clean Select button and grease O-ring
(see page 40)