* ATTENTION: FURTHER SETTING OF THESE PARAMETERS CAN BE DANGEROUS.
With the motors without a limit switch and/or encoder, adjust the sensitivity of the sensor that causes stoppage during the
slowdown phase.
** 1: minimum force/torque - 99: maximum force/torque.
The control panel avails of two anti-crushing devices: the amperometric sensor (adjusted by parameters PMO1/2-PMC1/2-PSO1/2-
PSC1/2) and the encoder (adjusted by the SEAV and SEAR parameters).
Using the Autoset procedure, the sensitivity of the amperometric sensor is adjusted by default, while the encoder (with default setting)
only activates if the gate stops completely following impact.
You are advised to only use a system at a time, giving preference to the amperometric sensor, whose response time is less.
MENU
Enables and disables automatic closure.
TCA
On: automatic closure enabled.
Off = automatic closure disabled
Enables or disables the shared function.
On: shared function enabled. The S.S. or transmitter impulse has no effect during the
IbL
opening phase.
Off: apartment complex function disabled.
Enables or disables the condominium function during TCA counting.
On: apartment complex function enabled. The PP or transmitter pulse has no effect during
ibca
TCA counting.
Off: apartment complex function disabled.
Select the operating mode of the "P.P. button" and the transmitter.
PP
On: "Operation"; OPEN> CLOSE > OPEN>
Off: "Operation"; OPEN>STOP>CLOSE>STOP>
Enables or disables pre-flashing.
pre
On: Pre-flashing enabled. The flashing light activates 3s before the motor starts.
Off: Pre-flashing disabled.
Enables and disables rapid closure.
On: rapid closure enabled. With the gate open or in the opening phase, intervention of the
SCL
photocell causes automatic closure 3 s after complete opening. Active only with TCA:ON
Off = rapid closure disabled
Person present function enabled or disabled.
On: Person Present Operation
htr
The APRE/CHIUDE button must be kept pressed throughout the manoeuvre. Opening the
STOP input stops the motor. All the safety inputs are disabled.
Off: Automatic/semi-automatic operation.
Selection of the flashing light operating mode during the TCA time
LTCA
On: Flashing indicator light on during TCA
Off: Flashing indicator light off during TCA
Sets the BLINK flashing output operating mode.
On: The output provides intermittent voltage during the manoeuvre phase (2 flashes per
MBLK
second).
Off: The output provides continuous voltage during the manoeuvre phase.
Enables or disables the photocells check on the PHOT Op input, enabled both in closure
and in opening.
On: Check enabled. If the check has a negative outcome, no manoeuvre is commanded.
TST1
See Fig.16/17 - "PHOTO TEST". (AUX=4)
Off: Check the photocells on each disabled manoeuvre. This setting requires maintenance
of photocells every 6 months.
Enables or disables the photocells check on the PHOT Cl input, enabled both in closure
and in opening.
On: Check enabled. If the check has a negative outcome, no manoeuvre is commanded.
tst2
See Fig.16/17 - "PHOTO TEST". (AUX=4)
Off: Check the photocells on each disabled manoeuvre. This setting requires maintenance
of photocells every 6 months.
COMPLY WITH LEGISLATION IN FORCE!
LOGIC (LOG)
FUNCTION
EN
ON-OFF-
MEMO
(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
31