LEAKAGE TEST
A gas leakage test must be performed again at the installation site. Please follow the procedure
below for leakage test.
• Make a soap solution of one part liquid detergent and one part water. The soap solution can be
applied with spray bottle, brush or rag. Soap bubbles will appear where a leak is present.
• Make sure the control tap is in the "OFF" position (full disk = ●) on the control panel.
• Turn on the gas supply and check for bubbles from the hoses and connections. If a bubble is
viable this means that a leak path is present.
• If a leak is present, turn OFF the gas supply immediately, tighten any leaking fitting carefully,
turn gas again and recheck.
• Never leak test whist smoking.
INSTALLATION
Important safety requirements:
THIS APPLIANCE IS FOR OUTDOOR USE ONLY
1. This appliance shall not be installed or used indoors, in buildings, garages or any other enclosed
area.
2. DO NOT place articles on or against this appliance.
3. DO NOT use or store flammable materials near this appliance.
4. DO NOT operate this appliance unless it is fully assembled with reflector and protection guard in
place.
5. Installation and repair should be done by a qualified service person. The appliance must be
inspected before use and at least annually by a qualified service person. More frequent
cleaning may be required as necessary. It is imperative that control compartment, burners and
circulating air passages of the heater and light be kept clean.
35