Operation Instruction – STICK/TIG Mode (Continued)
4
Setting Up for LIFT TIG Welding
□
Double check your input voltage:
For 120V: Switch voltage switch (Q) to 120V, use a 240V to
120V adapter while connecting to the 120V power source.
For 240V: Switch voltage switch (Q) to 240V, connect to
240V power source.
□
Connect the ground clamp cable to the positive (+) DINSE
socket (N) of the welder.
□
Ensure your workpiece is clean and dry and ensure the
ground clamp is well connected with the workpiece.
□
Follow instruction "Connecting the Gas Cylinder (TIG)" and
connect TIG torch gas line to gas cylinder.
□
Connect the TIG torch cable to the negative (-) DINSE
socket (M) of the welder.
□
Install the tungsten electrode into the TIG torch; fix it and
keep approximately 1/4 inch out of the torch nozzle.
□
Switch the ON/OFF switch (O) to ON at the back of the
machine.
□
Push the welding mode switch button (K) until LIFT TIG LED
turns on.
□
Set welding current by rotating the left knob (E).
□
Open the gas valve on the TIG torch.
□
The weld arc can be initiated by a lift arc technique.
□
When finished welding, close the gas valve on the TIG
torch.
□
When all welding is completed, close gas valve on the gas
cylinder.
LIFT TIG Welding Recommendation Table
Tungsten (Ce)
Material
Diameter
1/16 in.
Steel,
(1.6 mm)
Stainless
5/64 in.
Steel
(2.0 mm)
Cannot weld aluminum.
Recommended shielding gas: argon.
12
Amp
Amp
(120V)
(240V)
10-90A
10-180A
10-90A
10-180A