START-up
You receive a completely assembled magnetic core drilling machine and detailed operation manual. Please
check the condition of the goods on receipt for any transport damage, and make sure the delivery
is complete. Otherwise contact the manufacturer immediately.
!
Always read the operation manual before using the device for the first time!
1. First, check the cable and plug for damage, then insert the plug in the mains socket.
2. Push button MAGNET ON, in order to initiate the magnet and the magnetic adhesion is guaranteed.
3. When working on walls and ceilings, secure machine with safety belt.
For these operations we recommend cooling with our spray ALFRA BIO 4000, Prod.- No. 21040.
4. Push the button MOTOR ON to start the Motor.
5. To switch off the machine proceed in reverse order, first MOTOR OFF, then MAGNET OFF.
AdjuSTmEnT OF ThE ROTATiOn SpEEd
The machine has one gear with 2 mechanical reduction stages and a full-wave electronic.
At first you need to adjust the correct mechanical adjustment. Afterwards you need to adapt the rotation
speed with the help of the electrical rotation speed regulator.
If it's possible always choose the adjustment with low gear shifting and high engine speed.
Then the motor is set at a high torque and therefore it's protected against overheating due to high load.
ThERmO pROTEcTiOn
The thermo protection stops the motor when it's overheated automatically.
Afterwards you need to let it run with a high rotation speed at the idle speed for about two minutes.
14
For non-magnetizable
materials, please use
the ROTABEST Vacubest
(Prod.-No. 18150).