Descargar Imprimir esta página

Replacing / Cleaning The Quartz Sleeve - Astralpool Lyriox UV-C Manual De Instalación Y Funcionamiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 121
REPLACING / CLEANING QUARTZ SLEEVE
DANGER: ULTRAVIOLET RADIATION. Disconnect Power Before Replacing Lamp
ALWAYS ISOLATE THE UNIT FROM ANY ELECTRICITY AND WATER SUPPLY BEFORE
CARRYING OUT MAINTENANCE ON THE UNIT.
TO REMOVE A QUARTZ SLEEVE:
PLEASE NOTE: Removing the quartz sleeve will cause water to flow out of the unit.
Flow can be directed to the bypass using the installed bypass. If no bypass is installed then the
pump should be turned off and other valves used to isolate the UV.
1. Remove the UV bulb as described on page 15.
2. With the electricity supply disconnected, UV isolated and UV Bulb removed,
unscrew the locking nut at one end of the UV.
3. Carefully remove the quartz sleeve O-Ring and keep safe.
4. Unscrew the locking nut from the other end and remove the quartz sleeve O-Ring and keep
safe.
5. Carefully remove the quartz sleeve taking care not to allow it to drop inside the
UV body.
6. To drain any water that may be left in the unit, we would recommend that you unscrew the
mounting bracket(s), disconnect the unit from the pipework, and tilt the unit to drain the
chamber of water.
7. Clean the sleeve and polish with a soft cloth or paper towel. If you live in a hard water area,
you may get limescale on the quartz sleeve; this can be easily removed by using vinegar or a
cold water descaler.
WARNING: If the end caps / electrical connections get wet during this procedure,
please ensure that they are thoroughly dried before re-connecting.
TO RE-INSTALL A QUARTZ SLEEVE:
Follow the instructions on pages 9 and 12 to re-install the quartz sleeve and UV bulb.
IMPORTANT: After checking all the fittings are correctly tightened you can switch your unit back
on.
TROUBLESHOOTING (Also see page 18)
During this procedure or if you notice water leaking from around the end caps you should check
the following:
1. Check the O-Ring is undamaged.
2. Check there are no cracks and breaks in the quartz sleeve.
3. Check that the locking nut is compressing the O-Ring to form a water tight seal.
4. Check that the end caps are sufficiently tight.
5. All components are clean and free from dirt and debris.
*Please note that service items are not subject to a claim under warranty. The service items