3.2.3 REMOTE SCALE CONNECTION

The charging cell cable is connected to the 9-pin D-sub-miniature plug connector with the following connections:
Numbers Pins
Pin 1,2
Pin 4,5
Pin 8
Pin 7
Pin 3
3.2.4 MOUTING REMOTE SCALE
The remote scale must be mounted for a realistic resolution with respect to the input provided by the load cell (s).
The balance remote can mount a resolution high with a maximum of 1/30,000, per example: 300kg x 10g always what the cells what allow. also be possibly
make a test in the balance remote with the same precision what with the local.
When is used more of a cell of load o the total of the capacity of the cell of load no is used then is must select a resolution reduced in the mounting techni-
cal of the balance remote. For example, if a system used four cells of load 2mv/v 1000kg for a balance of capacity of 1000 kg then the tension of exit with
the balance a stop be only of 2.5mv. In this case the resolution must be reduced for provide a good number of account pieces by division shown by exam-
ple mounted a1:5000 o 1000kg x 0.2kg. Establish a high resolution without provide a good input at the balance remote no the provide a greater precision y
can cause a the balance difficulties in finding the specifications of performance.
For best use, ensure a minimum of 0.1 µv/d.

4. KEYBOARD DESCRIPTION

Cancel or delete:
is sample the total.
M+:
This button is used for adding the amount current to accumulator. also remember the memory when is press y there's none no load
about the balance. Until 99 values or capacity maximum of weight shown can added. also prints the values shown when you turn off auto
print.
Smpl:
This is used to enter the number of objects in the sample.
PLU:
To store and remember the information shows.
U.Wt/ Units
PST:
For establish the limit higher of number of objects counted. when is exceeds The Limit Maximum Sound In The Balance a sound. A
function secondary it the of use for establishing the control of the backlight.
Local/Rem:
Tare:
Is tare the balance storing the weight current in the memory as a value tare, subtracting the value tare of weight total and showing
the results as weight NET.
Cero:
Sets the zero point for all subsequent weighing by setting the screen to zero.
Connection
Power 0V
Power +5V
Signal -
Signal +
Mesh
:
Keys numerical
used for introducing manually a value for the weight of tare, weight unit and size of sample.
FUNCTION SECONDARY: a function secondary is for introduce characters alphanumeric for descriptions liked etc.
By pressing this button is deletes the unit of weight a input wrong. Also deletes the memory of accumulation when
:
This button is used to enter the sample weight manually. it will also change the weight units when other units are used.
This button is used to select the local or remote scale.
OPERATION MANUAL BCD
EN
EN
23