Malfunction
The nose piece hasn't
returned into its initial posi-
tion after driving a nail.
No nails are driven, but the
fan is running.
No nails are driven, and the
fan is not running.
Possible cause
A nail jam has occurred in the
nose piece.
Nail transport is not working
anymore.
Fuel cell is empty.
Incorrect position of the driving
piston.
Frequent incorrect position of
the driving piston.
The tool doesn't drive due to a
dirty spark plug.
The high voltage cable for the
spark plug got loose.
Not enough nails in the
magazine.
The battery is discharged.
The electric cable of the fan
became loose.
Action to be taken
→ Clear the nail jam with e.g. a screwdriver.
→ Check the nail strip, if damaged use a new
one. Clean the magazine and the nose
piece.
→ Insert a new fuel cell.
→ Push back the driving piston all the way into
its initial position.
→ Clean the tool as described in chapter 8.
→ Clean the tool as described in chapter 8.
→ Open the back of the tool and plug in the
high voltage cable again.
→ Load new nails into the magazine.
→ Change the battery with a fully charged one.
→ Open the back of the tool and plug in the fan
cable again.
EN
41