Descargar Imprimir esta página

EAS ELECTRIC EINSOLAR36Y Manual De Usuario E Instalacion página 27

Ocultar thumbs Ver también para EINSOLAR36Y:

Publicidad

Idiomas disponibles

Idiomas disponibles

Inverter power quality response modes
Power quality response
modes
Volt-watt response mode
Volt-var response mode
Fixed power factor mode
Reactive power mode
factor curve for cos φ (P)
Characteristic power
Default operation per AS/
NZS 4777.2:2015
Default: Enabled
Default: Disabled
Default: Disabled
Default: Disabled
Default: Disabled
22
10. TROUBLE SHOOTING
Earth Fault Alarm
This inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm
monitoring. If an Earth Fault Alarm occurs, the error code 6 will be
displayed on the LCD. Red LED indicator will also light up.
If an external indication of earth fault alarm is required, please connect PV
System to inverter monitoring app/portal. The monitoring platform will
send email notification in the event of an Earth Fault. Please refer to Sector
6.1 and the Wi-Fi stick guide on how to setup your inverter communication
function.
Full Error Code and Corrective Measures
When the PV system does not operate normally, we recommend the
following solutions for quick troubleshooting. If an error occurs, the Error
code will be displayed on the inverter's screen or on the monitoring App/
Web, the red LED will light up. The corresponding corrective measures are
as follows:
Error Code
Fault Name
Functional
fault in
Micro-
1
Controller
Unit (MCU)
A faulty
current
sensor
2
detected
Ground fault
circuit
3
interrupter
(GFCI)
V.2
Description
Corrective Measures
Disconnect the inverter from the utility
MCU abnormal
grid and the PV array, and reconnect it
self-check in
after LED turns off. If this fault is still being
start process
displayed, please contact service.
Disconnect the inverter from the utility grid
AC current sensor
and the PV array, and reconnect it after
detect current
LED turns off. If this fault is still being
abnormal in the
displayed, please contact service.
start process
Disconnect the inverter from the utility
GFCI sensor self-
grid and the PV array, and reconnect it
check abnormal
after LED turns off. If this fault is still being
displayed, please contact service.
23
V.2

Publicidad

loading

Este manual también es adecuado para:

Einsolar50y