MAINTENANCE
Cleaning Impeller and Volute
Periodic cleaning of the pump parts will prolong the life and efficiency
of the pump.
s
WARNING
!
1.
housing cover. Warranty is void if the motor housing cover,
impeller or seals have been removed.
2. Remove all debris (gravel, sand, floating debris, etc.) from the
sump basin.
3. Clean the impeller and the volute passage (1). Do not use
strong solvents.
s
CAUTION
!
a.
impeller. Removal of the impeller requires special tools and
is to be done only by an authorized service center.
4. Be sure the impeller turns freely after cleaning.
CONNECTIONS FOR PUMP OPERATION
Manual Operation
Disconnect the pump cord from the float switch extension and plug it
directly into the GFCI outlet.
s
CAUTION
!
only for emergency use or when a large volume of water is to be
pumped. Pump must not be allowed to run dry. If pump is run dry, it
may damage pump and void the warranty.
Automatic Operation
Plug the pump cord into the float switch extension. Plug the float
switch cord (with pump cord attached) into the GFCI outlet.
8
Do not remove the motor
Do not remove the
This type of operation should be used
REPLACEMENT PARTS
Part No.
Description
14942904
Vertical Switch, Piggyback 10'
1
Manual
Operation
Item No.
2
2
Automatic
Operation