These are the lower and upper values of your lamp dimming
temperature. The Light controller starts to dim with the first Temperature
settings and stops to dim according the second temperature. Between this
two temperature you must have a hysteresis (band-with) that the controller
have minimal range to dim of 1° between this two values.
These are the lower and upper dimmable values. The first setting is the
maximum power up to 100%. The second setting is the lowest dimmable
value.
Repeat the settings in the same way: ENTER to change the first setting
maximum dim % with the arrows UP/DOWN. SAVE/EXIT to save and return
or ENTER to set the dim minimal dim % which is the lowest dimmable value.
[This minimal dimmable value you have to find out according to the product,
the lamp should not shut OFF at this lowest point!]
In this shut down setting you choose when the lights should go off
according to the temperature. This is like a emergency stop because of
overheating. This value can be set how you like but it is recommended to
keep it higher as the upper dimmable value. The shut down value can not be
smaller +1° as the restart temperature.
Push ENTER the temperature value starts to blink, change the value
with the arrows UP/DOWN and push set save to return to the sub menu.
Here you choose the restart temperature after the emergency shut
down. This value can not be greater as Shutdown temperature -1°
Push ENTER the temperature value starts to blink, change the value with
the arrows UP/DOWN and push SAVE/EXIT to return to the sub menu.
This function has been designed to prevent a HPS or MH bulbs from
hot-start. Once the Shut down temperature got triggered the timer starts a
count down. Even if the temperature reaches the restart temperature level
before this time has elapsed it will prevent from restarting the lamp.
Push ENTER the time in minutes starts to blink, change the value with the
arrows UP/DOWN and push SAVE/EXIT to return to the sub menu.
GSE Light timer
Set dimming temperature
Set dimming range
Shutdown temperature
Restart temperature
Cool down time