OPERATION
• Press the anti-blocking push-button to operate. Automatic timed shut-off.
INSTALLATION
• For the UK market, the flush valve must be supplied by a centralised tank and a pump that ensures a dynamic
pressure of 1.2 bar minimum.
• Pressure: 1 bar (100kPa) to 5 bar (500kPa), we recommend 3 bar (300kPa).
• Required operating flow rate: 1 l/sec.
• The electrical installation must conform to local Electrical Regulations/Standards.
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
• Our products are compatible with grey and sea water as long as both are filtered and have a pH number
between 6.5 and 9.5.
RECOMMENDATION FOR INSTALLATION OF PLASTERBOARD
• Cross over the plasterboard so the joints are spread over the different thicknesses (see fig. K2 page 7).
ADJUSTING THE FLOW RATE
The flow rate can be adjusted from 2 to 9L:
• Turn the lever on the stopcock (fig. K page 15) as well as the adjustment cog-wheel behind actuator plate
(fig. P1 and P2 page 16) until the required flush volume is achieved.
REMEMBER
• Our valves must be installed by professional installers in accordance with current regulations and
recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar (100 to 500 kPa) maximum).
• Install stopcocks close to the valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/tap/valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN
20

Publicidad

loading

Este manual también es adecuado para:

Tempoflux 3