Descargar Imprimir esta página

Enerco H100 Instrucciones De Funcionamiento Y Manual Del Propietario página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure
13
Manufactured Chimney through Masonry Wall
Insulated
Single-Wall
Figure 14
Manufactured Chimney through Attic
Wood Fire Stove
EXISTING FIREPLACE INSTRUCTIONS & DIAGRAM
This stove may be vented through a fireplace with flue
liner (clay tile which protects chimney) only if all of
the warnings, requirements and processes below are
obeyed. Installation should be executed so that the
system can be dismantled for periodic cleaning and
inspection.
WARNING: VENTING A STOVE INTO
A FIREPLACE BY ANY METHOD NOT
EXPLICATIVELY COVERED, OR WHICH
OTHERWISE DOES NOT SATISFY LOCAL
CODES, SHOULD NOT BE ATTEMPTED.
DOING SO WILL VOID THE WARRANTY ON
THIS STOVE, AND MAY CREATE A HAZARD
IN YOUR HOME.
CAUTION: HAVE A QUALIFIED EXPERT
INSPECT THE FIREPLACE CHIMNEY AND
APPROVE IT FOR CONVERSION FOR USE
WITH A WOOD STOVE.
NOTE: MANY FIREPLACES ARE DESIGNED TO
WITHSTAND CONTACT WITH COMBUSTIBLES AT
THE FLOOR BUT MAY NOT HAVE BEEN TESTED
FOR USE WITH A WOOD STOVE. CONNECTION
OF A WOOD STOVE TO FIREPLACE CHIMNEY
MAY VOID EXISTING WARRANTY ON THE
FIREPLACE CHIMNEY.
1. Inspect the chimney. Any questions regarding the
condition of the chimney may be directed at a
qualified licensed contractor, qualified engineer,
competent mason, certified Chimney Sweep, or
knowledgeable inspector. The chimney must be:
• Structurally sound
• Equipped with flue liner that is in good
condition. If the chimney is unlined or
damaged it can not be approved for
conversion for use with this wood stove.
• Able to be secured and sealed at the throat
damper and (if present) clean out or other
openings at the base of the chimney which
could leak the pressure seal.
2. If the connection piping from the stove to a
masonry chimney is to be made through a
combustible wall, consult a qualified mason or
chimney dealer for consultation. To ensure safety,
the installation should only be done by a qualified
installer. The installation must conform to the
regulations established by local fire codes and
building codes.
E12