INSTALLING THE BLOWER (OPTIONAL) - continued
6. Snap Switch into opening in control panel, making sure
to position the Auto function on top. Wire clips and a
cable tie are provided to help keep the wire harness
away from the hot firebox and burner (see Fig. 10).
The Blower is equipped with manual ON, OFF and AUTO
switch (see Fig. 8). In the Auto position the Blower will
automatically come on a few minutes after the burner
comes on and will shut off a few minutes after the burner
shuts off.
NOTE: If any of the original wire supplied with the heater
must be replaced, a wire of at least an equal temperature
rating must be used. Refer to Fig. 11 for the wiring diagram.
Label all wires prior to disconnection when
CAUTION
CAUTION
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after
servicing.
Installation (cont.)
17
Fig. 10—Installing Switch and
securing wires
Fig. 11—Fan Wiring Diagram
Vent-Free Gas Fireplace User's Manual