Electrical safety
Always check that the voltage of the power
supply corresponds to the voltage on the
rating plate.
• Do not use the machine if the mains cable or
the mains plug is damaged.
• Only use extension cables that are suitable for
the power rating of the machine with a minimum
thickness of 1.5 mm
. If you use an extension
2
cable reel, always fully unroll the cable.
2. MACHINE INFORMATION
Intended use
The machine is intended for driving in and loose-
ning screws and bolts as well as for tightening and
loosening nuts whilst adhering to the technical
data. Main purpose environment is in the automo-
tive sector, for metal construction or roofing work.
The device is not intended for drilling.
TECHNICAL SPECIFICATIONS
This manual has been drawn up for
different sets / article numbers. Check the
corresponding article number in below
specifications table for the correct
composition and contents of your set.
Batteries
Model No.
included
IW502DC
-
S_ IW502DC
CD801AA
S2_ IW502DC
2 x CD801AA
S3_ IW502DC
CD803AA
Machine information
Rated voltage
Chuck
Torque 1st setting
Torque 2nd setting
Torque 3rd setting
Torque 4rd setting (max)
Weight
No-load speed
No-load impact rate
WWW.VONROC.COM
Chargers
included
-
CD802AA
CD802AA
CD802AA
20V
1/2" square chuck
100Nm
200 Nm
300 Nm
400 Nm
1,8 kg
0-2300/min
0-3000/min
Sound pressure level L
PA
Sound power level
LWA
Vibration
Model No.
Battery Type
Voltage
Capacity
Recommended charger
Weight
Model No.
Charger input
Charger output
Charging time 2Ah battery
Charging time 4Ah battery
Recommended batteries
Weight
Model No.
Battery Type
Voltage
Capacity
Recommended charger
Weight
Only use the following batteries of the VONROC
VPOWER 20V battery platform. Using any other bat-
teries could cause serious injury or damage the tool.
CD801AA
20V, 2Ah Lithium-Ion
CD803AA
20V, 4Ah Lithium-Ion
The following charger of the can be used to charge
these batteries.
CD802AA
Quick charger
The batteries of the VONROC VPOWER 20V battery
platform are interchangeable with all the VONROC
VPOWER 20V battery platform tools.
Vibration level
The vibration emission level stated in this instruction
manual has been measured in accordance with
a standardized test given in EN 62841; it may be
87.64.8 dB(A) K=3 dB(A)
97.64 dB(A), K=3dB(A)
7.41 m/s2 K=1.5 m/s2
CD801AA
Lithium-Ion
20V
2.0 Ah
CD802AA
0.3 kg
CD802AA
220-240V, 50Hz 0.4A
21V
2.5A
60 minutes
120 minutes
CD801AA, CD803AA
0.36 kg
CD803AA
Lithium-Ion
20V
4.0 Ah
CD802AA
0.65 kg
7