6. INTRODUCTION
The GE 25 is a next-generation high-efficiency portable electric inflator, which stands out for
reliability and functionality. The inflator features 2 stages that can be identified by the different noise:
turbine noise at the beginning and piston noise later on. Turbine stage automatically switches to
piston stage. The inflator starts when the ON button is pressed and automatically stops when the set
pressure in the pressure gauge is reached. The device stops when the user presses the OFF button.
The GE 25 SL and GE 25 HP are fully portable inflators as the battery is integrated in the device.
When the battery is low (red light on pressure gauge), it can be recharged using 110-240 AC/DC
transformers.
The GE 25 AC requires a 120 V - 60 Hz or 230V – 50 Hz power supply, as specified on the
nameplate.
The unit is protected against overheating. In the event of high outside temperature or overuse, the
inflator will automatically stop and a red LED on the pressure gauge will indicate its status. The
device can be restarted when the red LED goes OFF.
7.RECOMMENDED USES
Large inflatable objects such as surfboards / rubber dinghies / kayaks / kites / etc.
rafts / air mattresses / swimming pool floats / etc.
8. TECHNICAL SPECIFICATIONS
FLOW RATE
ITEM
(L / minute)
425 (fan)
GE 25 SL
250 (compressor)
425 (fan)
GE 25 HP
250 (compressor)
425 (fan)
GE 25 AC
250 (compressor)
Pressure settings
Battery charger socket
Power cable
Inflation fittings
Carry bag dimensions
GE 25 SL batteries
GE 25 HP batteries
9. INFLATOR USE
ACCESSORIES AND POWER CABLES
1. Accessories, like the 110-240V battery charger and the relevant adapters, can be found in the
top compartment of the carry bag.
CONNECTION
2. Ensure that the OFF button has been pressed (LED off on pressure
gauge) and that the main switch is off (GE 25 AC only).
3. Connect the air hose to the inflate port (OUT) or to the deflate port
(IN), making sure that the tabs are properly fastened (see picture)
5. Assemble the most suitable adapter for the inflator valve.
TO INFLATE
1. Connect the hose to the outlet port (OUT)
2. Set the desired pressure on the pressure switch.
3. For GE 25 AC only: press the main switch (point 1, fig. on p.3)
For GE 25 SL and GE 25 HP: press the ON button (point 2, fig. on p.3)
4. The device starts and the LED on pressure gauge becomes GREEN. The inflator will automatically
stop when the float reaches set pressure.
12
SAFETY FUSE
MAX. PRESSURE
FUNCTIONS
(mbar)
INFLATION /
40 A
1500 (22 PSI)
DEFLATION
INFLATION /
40 A
1500 (22 PSI)
DEFLATION
INFLATION /
40 A
1500 (22 PSI)
DEFLATION
Pressure gauge with automatic switching off
Jack type (for GE 25 SL and GE 25 HP only)
3 m long cable (for GE 25 AC only)
Available for most common valves
395x180x240 mm
No. 2 Sealed Lead-Acid Batteries - 12V 9Ah
No. 2 LiFePO4 Batteries - 12.8V 8Ah
TO DEFLATE
1. Connect the hose to the inlet port (IN)
2. Set the pressure on the pressure switch to zero.
3. For GE 25 AC only: press the main switch (point 1, fig. on p.3)
For GE 25 SL and GE 25 HP: press the ON button (point 2, fig. on p.3)
4. The device starts and the LED on pressure gauge becomes GREEN.
5. Press the OFF button as soon as the float is completely deflated.
WARNING
DEFLATION DOES NOT STOP AUTOMATICALLY. SWITCH OFF THE INFLATOR ONCE THE INFLATABLE UNIT IS COMPLETELY
EMPTIED.
WARNING
(for GE 25 SL and GE 25 HP only): If the LED on pressure gauge becomes YELLOW or RED, press the OFF
button, connect the inflator to recharge the battery.
Be careful when connecting the cable to the battery, in order not to short the battery with conducting
materials such as rings, bracelets and keys. The battery or adapter may overheat and cause injury.
Check the voltage. Do not connect the 12V inflator to a 24V battery.
Do not leave the inflator running unattended. Overinflating an object could result in serious injury.
THE INFLATOR CAN BE DAMAGED BY SAND, DUST OR WATER GETTING INSIDE THE INLET PORT. THIS
WILL CAUSE OVERHEATING AND WILL DAMAGE THE TURBINE. SHOULD THIS BE THE CASE, IMMEDIATELY
SWITCH THE INFLATOR OFF.
11. TROUBLESHOOTING
POSSIBLE CAUSE
PROBLEM
GE 25 SL/GE 25 HP battery LOW
The ON button has not been pressed.
The inflator does
not start
The safety fuse is blown
The device is damaged
Hose wrong connection.
Wrong pressure setting
The inflator
does not inflate/
deflate
Battery LOW with yellow or red LED ON
11.1 ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.
POSSIBLE SOLUTION
Recharge the battery using the 110-240V
battery charger.
Press the ON button.
Replace the fuse with one of the same
type (30 A)
Contact a SCOPREGA service
centre.
Connect the air hose to the
correct port.
Correct pressure setting.
Recharge the battery using the 110-240V
battery charger.
13