Security edge connection
No. of security edges connected
Open
-
-
1
1
Programming
•If, during programming, a stoppage is made, the open security contact is enabled or any similar event occurs, the con-
trol panel will automatically exit programming for security reasons.
•Before starting any type of time programming, it is wise to have the corresponding options correctly selected.
•Operations can be programmed indifferently using the TEST button, the START button or through a transmitter already
programmed.
Operation time programming
Close the door with the limit switches duly connected.
Press the TIMER PROG button to enter programming. The PROG led with light up and the equipment will emit an acoustic
signal. Use the TEST button, the START button or a transmitter to programme the run. First time it is pressed, it opens. The
second time it is pressed, the opening movement slows down until a mechanical stop or the end of run open is reached and
the automatic standby TIMER begins. The third time it is pressed, it stops the automatic standby TIMER and closes. The
fourth time it is pressed, the closing movement slows down until a mechanical stop the end of run close is reached and pro-
gramming is exited. The PROG led light goes out and the equipment will emit two acoustic signals.
Programming for pedestrian function
Close the door with the limit switches duly connected.
Press the TIMER PROG button to enter programming. The PROG led with light up and the equipment will emit an acoustic
signal. Use the pedestrian button (PED.) or a transmitter with pedestrian function programmed to programme the run. First
time it is pressed, it opens. The second time it is pressed, the opening movement slows down until a mechanical stop or the
end of run open is reached and the automatic standby TIMER begins. The third time it is pressed, it stops the automatic
standby TIMER and closes. The fourth time it is pressed, the closing movement slows down until a mechanical stop the end
of run close is reached and programming is exited. The PROG led light goes out and the equipment will emit two acoustic sig-
nals.
N.B.: Options 1, 5, 6 and 7 of the option switch programmed in normal operations will be valid for partial opening.
Close
-
Default option
1
Turn option 4 on the input switch to OFF
-
Turn option 3 on the input switch to OFF
1
Turn option 3 and 4 on the input switch to OFF
jcmtechnologies
6
Connections