02
500-720 mm
A
≥ 460 mm
EN
Mark the wall with the hole positions as shown in the diagram. The fixings supplied are suitable for
solid walls only. When fixing to any other type of wall use suitable alternative fixings.
WARNING: Caution! Before drilling it is extremely important to check the wall for hidden pipes
and electrical cables using an appropriate detection device. Ensure that all safety distances to
flammable materials are followed as shown above.
Drill the holes, insert the wall plugs in all 6 holes. Insert the screws in the holes in the second row
from the bottom. The maximum gap between row two and row three from the bottom should be
between 500-720 mm, dependent upon the ceiling height.
WARNING: Use only the same size of fittings and mounting screws as recommended in this
instruction manual. Failure to follow these instructions may result in electrical hazards.
WARNING: Please follow the Safety and Electrical Installation sections at the start of this manual
before connecting this appliance to the mains supply!
5059340446189_MNL_IN_V03.indb 56
5059340446189_MNL_IN_V03.indb 56
75 mm
188 mm
700-920 mm
121 mm
400 mm
61 mm
56
≥ 760 mm
A
≥ 650 mm
8/6/2022 3:27 PM