FILTER
This appliance is equipped with 3 types of filters:
Prefilter
Frequency of cleaning/replacing the filter :
Filter
3-in-1 pre-filter, allergy+ filter
and active carbon
The recommended frequency for replacing the filter may vary depending on the duration of use
and the operating environment.
IMPORTANT:
The filter change indicator (6) is lighted when the filter needs to be replaced. Once the filter has
been replaced, hold down the button for 3 seconds.
Forced reset:
If you have replaced the filter before its end of life, force the reset of filter cycle:
1. Hold the filter change indicator (6) for 3 seconds.
2. The indicator is lighted. Hold down the button for 3 seconds, to reset the filter cycle.
« TIPS FOR CHANGING FILTERS »
• Avoid handling used filters if you suffer from allergies or asthma.
• Wear gloves when changing the filters, or wash your hands well afterwards.
• Put used filters directly into a closed, air-tight bag before throwing them away to
avoid spreading pollutants.
POLLUTION SENSOR
The particles sensor need to be cleaned regularly (every 2 months) and appropriately.
Make sure you turn off and unplug the appliance before cleaning the pollution sensors and follow
the recommendations below:
1. Clean the air inlet and outlet using a soft brush or cloth.
2. Open the sensor cover located on the right-hand side of the appliance.
3. Lightly wet a cotton swab and remove any dust from the lens and the inlet/outlet. Wipe using
a dry cotton swab.
4. Clean the sensor using a soft brush or vacuum cleaner.
5. Replace the sensor cover
10
Active Carbon
Particle filter
NanoCaptur+
filter
Action
Cycles
Every 12 months or when the
Replace
filter change indicator is lighted
1
IMPORTANT:
• Never use a detergent or metal object to clean the sensors.
• The efficiency of the sensors may be reduced if not cleaned regularly.
• Cleaning frequency varies depending on the operating environment of the appliance. If it is
filter
used in a dusty environment, clean the sensors more frequently.
STORAGE
When you are not using the appliance, store it in a cool, dry place with ambient conditions no
higher than 35°C 70%RH.
IN THE EVENT OF A PROBLEM
• Do not disassemble the appliance yourself. A poorly repaired appliance may be dangerous for the user.
• Check the troubleshooting table below before contacting an Approved Service Center:
Problem
The appliance does not
switch on.
The air flow does not
change automatically.
The flow is a lot weaker
than before.
There is an unpleasant
smell coming from the
air outlet.
The air quality indica-
tor does not change
color.
2
3
4
Check
Connect the power cord to a plug with
Is the power cord connected?
Press the on/off button and select the
Are all the display elements off?
You can use your purifier once the
Is these a power outage?
Is the appliance in manual
Select the correct operating mode.
mode?
Does the filter need to be
frequencies and replace the filter if
cleaned or replaced?
Does the light still indicate poor
frequencies and replace the filter if
air quality?
Is the sensor lens covered with
Clean the sensor lens with soft
dust?
EN
5
Solution
the correct voltage.
required function.
power turns on again.
Check the filter replacement
necessary.
Check the filter replacement
necessary.