2. Before installation
2.1 Prerequisites
The installation of electrical systems must be performed by specialized personnel.
•
The cabinet must be installed stably and perfectly level. Any deformity or instability in the cabinet may pose a risk to user safety and
system operation.
•
Check the correct functioning of the sliding system to be combined with 'B-Moved' and the correct positioning of track limit stops.
•
Each movement bar is equipped with a 4-metre cable for connection to control unit. The control unit power supply cable has a length
of approximately 3 metres including the power adapter. A 110-240V, 50-60Hz, AC power outlet must therefore be accessible near
to where the cabinet is installed.
•
The installed electrical system must comply with applicable regulations regarding active and passive electrical protection.
2.2 Electrical connection
Make sure that the power outlet is easily accessible after installing the cabinet and system.
All connections must comply with the regulations of energy supply companies.
3. Set-up operations
3.1 Initial cabinet set-up
Do not power the control unit until all motors have been connected.
Connect all movement bar motors to the control unit according to the chosen cabinet configuration.
After connecting all the motors to the control unit according to instructions, manually bring the doors to their closed positions.
3.2 Control unit power supply
After checking the correct connection of the motors to the control unit and
bringing the doors to their closed positions, the control unit can finally be
powered via the power supply unit.
Wait at least 10 seconds after powering on the unit
00:00:10
to allow it to learn and select the program to use
with the connected system.
3.3 Track memorization cycle
Activate the function for automatic detection of door track limits, as
described in Section 2.3, by long pressing (3 seconds) the 'SET/RESET'
button on the control unit.
One door at a time, starting from the first door to the left of the cabinet, the
doors will move slowly towards their respective track limit stops.
The operation may take up to a few minutes until all door tracks have been
memorized.
During this set-up phase, the movement of the doors must not be
impeded in any way.
If the positions of the track limit stops are changed, the track
memorization cycle must be repeated.
During this set-up phase, the remote control pairing function cannot
be activated.
If this operation is not successful due to a lack of power or physical
obstacles in the path of the door, simply unplug the power supply,
bring the doors to their closed positions and repeat the operation.