Descargar Imprimir esta página

Calpeda I-MPC Instrucciones De Uso página 18

Bombas autocebantes para piscinas a velocidad variable con control integrado

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
(14.24) with the nuts (14.28) must be uniformly
tightened with alternated crossover tightening in
diametrically opposed positions. Tightening torque for
screws (14.24): 7 Nm.
10. DISPOSAL
EN
OFF
The final disposal of the device must be done by
specialized company.
Make sure the specialized company follows the
classification of the material parts for the separation.
Observe the local regulations and dispose the device
accordingly with the international rules for environment
protection.
11. SPARE PARTS
11.1.
Spare-parts request
When ordering spare parts, please quote their
designation, position number in the cross section
drawing and rated data from the pump name plate
(type, date and serial number).
The spare parts request shall be sent to CALPEDA
S.p.A. by phone, fax, e-mail.
12. ESIGNATION OF PARTS
Nr.
Designation
14.00 Pump casing
14.14 Plug
14.15 O-ring
14.20 O-ring
14.24 Screw
14.28 Nut
14.29 Washer
15.00 Strainer cover
15.04 O-ring
15.12 Hand wheel
15.16 Square nut
13. ALARMS
Error reset can be automatic or manual, depending on the error that occurs. Manual reset is carried out using the
enter button and then start to restart the pump.
Code
Description
Er03
Blockage due to low supply voltage
Er04
Blockage due to high supply voltage
Blockage due to overcurrent in the electro
Er06
pump motor
Er07
Pump not fully primed
Er08
Blockage due to internal overheating
Er10
Thermal-protector intervention detected
From Er26
Internal hardware error
to Er31
In case of internal hardware error contact an authorised service centre.
Page 18 / 88
European Directive
2012/19/EU (WEEE)
15.50 Strainer basket
27.00 Diffuser cover
27.04 Diffuser funnel
27.08 O-ring
28.00 Impeller
36.00 Mechanical seal
70.00 Lantern bracket
73.00 Ball bearing
73.08 V-ring, pump side
76.00 Motor casing with winding
76.16 Support
76.30 Base appoggio
76.31 Screw
76.30 Dado
78.00 Shaft with rotor packet
81.00 Ball bearing
82.00 Motor end shield
82.04 Compensating spring
88.00 Motor fan
90.00 Fan cover
90.04 Screw
92.00 Tie-bolt
96.02 Cable with plug
98.00 Terminal box cover
98.04 Screw
98.08 Gasket
98.20 Screw
98.54 Display cable
98.55 Terminal box cover / board
98.60 Control board + Input signal board
98.63 Power board
98.70 Screw
98.71 Screw
Reset
Causes
ERR
Supply voltage lower than 185V.
AUT
- The system restarts automatically when the
supply voltage is higher than 190V.
Supply voltage higher than 255V.
AUT
- The system restarts automatically when the
supply voltage is lower than 250V.
The system tries to restart automatically and
MAN
makes one attempt every 10 seconds for a
total of 3 attempts.
MAN
Priming attempt failed
Overtemperature detected on the board. The
AUT
error is restored when the temperature drops.
MAN
Motor overheating
MAN
I-MPC Rev1 - Operating Instructions