Descargar Imprimir esta página

Lavor NEXT EVO Manual De Instrucciones página 43

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 87
9. OPERATING CHECKS
9.1
MALFUNCTIONS SELF-DIAGNOSTIC
The display located on the control panel (Photo 7)
also has the function of showing any active alarms
on the machine concerning to the control board
operation; in case of alarm will be shown the code
Alarm # id
1. Traction motor shutdown
2. Brushes motor shutdown
3. Suction motor shutdown
4. Traction motor I
2
gered
5. Brushes motor I
2
gered
6. Suction motor I
2
gered
7. Brushes motor switch off
for run down battery
8. Suction motor switch off
for run down battery
9. Machine stop for run
down battery
10. Machine stop for over
charged battery
11. Board temperature too
high (traction stopped)
13. Board temperature too
high (traction lowered to
50%)
14. Floating switch error
15. Start error (key switch
on with operator presence
pressed)
16. Solid board in standby
18. CanBUS communica-
tion interrupted
27. Traction motor discon-
nected
28. Battery overcurrent
29. Low battery current
Meaning
Amperometric protection
traction motor
Amperometric protection
Brushes motor
Amperometric protection
suction motor
t trig-
Amperometric protection
traction motor
t trig-
Amperometric protection
Brushes motor
t trig-
Amperometric protection
suction motor
Low voltage
Low voltage
Low voltage
Overcurrent
Control board overheating
(traction stopped)
high temperature detect
on control board (traction
lowered to 50%)
Stop signal from floating
switch
User lever pressed before
control board check
Control board freeze status
for excessive stand-by
Lack of communica- tion
dashboard-board
No traction motor signal
Overcurrent
Low voltage
and a brief description of the error.
Here below is the list of error messages with the
corresponding diagnostic:
Solution
Check usage mode of the traction function. High working
current has been detected by the traction motor.
Check usage mode of the brushes function. Detected ele-
vated work current by the brushes motor.
Check vacuum motor absorption. Detected elevated
work current by the suction motor.
Check usage mode of the traction function. High working
current has been detected by the traction motor.
Check usage mode of the brushes function. Detected ele-
vated work current by the brushes motor.
Check vacuum motor absorption. Detected elevated
work current by the suction motor.
Low voltage detected on function board (<90%).
Check batteries and batteries connections.
Low voltage detected on function board (<80%).
Check batteries and batteries connections.
Low voltage detected on function board. Check batte-
ries and batteries connections.
Overvoltage detected on function board. Check batte-
ries and batteries connections.
check brush motor/traction motor absorption
check brush motor/traction motor absorption
To empty recovery tank
Reboot scrubber drier (do not press user lever before
control board check)
Reboot scrubber drier
Check connections between the function board and da-
shboard.
Check connections and traction motor status.
Overvoltage detected on function board. Check batte-
ries and batteries connections.
Low voltage detected on function board. Check batte-
ries and batteries connections.