7.3 Troubleshooting
Fault
Product does not
switch on
LED signal light
without function
Product restarts
every minute
LED signal light
flashes
red/green/blue
LED signal light
flashes red
A section of the
LED signal light
lights up blue
1502724-02
Cause
No power supply available
The control does not
receive any data from the
sensors
Both sensors do not
provide any measured
values
No mobile wireless
connection
Interference signals from
external devices
Tab. 20: Troubleshooting
- 63 -
Note
Check the plug-in power
supply unit
Check the adapter +
connection cable on the
product
Sensor board defective
Sensor board not
plugged in correctly. To
do this, open the cover on
the product and check
that the sensor board is
seated correctly.
Press the reset button for
1 second to acknowledge
the error.
Sensor board defective
Sensor board not
plugged in correctly
Press the reset button for
1 second to acknowledge
the error.
Restart product
Check the seating of the
mobile wireless antenna.
Check mobile wireless
network, change product
location if necessary.