Descargar Imprimir esta página

Levenhuk Wezzer SN80 Guia Del Usuario página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
Levenhuk Wezzer SN80 Sauna Thermometer
EN
Caution! Please remember that mains voltage in most European countries is 220–240V. If you want to use your device in a country with a
different mains voltage standard, remember that use of a converter is absolutely necessary.
Getting started
Connect the power cable to the device and the DC adapter (not included) via a USB plug and connect to the AC power supply.
Extend the wired probe into the sauna room to measure the temperature there. Attention! The main unit should be installed in a place at
which a maximum temperature of +80°C is not exceeded.
Thermometer functions
Press the SET button and hold it for 3 seconds. Highlight the desired menu item by scrolling up (UP button) or down (DOWN button). Select
the highlighted item by pressing the CONFIRM button. Press UP or DOWN to change the value, and then press the CONFIRM button to save
the settings.
In the menu, you can set the time, set the upper and lower temperature and humidity limits, and switch the alarm on or off.
Thermometer calibration
Press the UP and DOWN buttons simultaneously and hold them for 3 seconds. Then press the CONFIRM button to calibrate the device
manually. Press UP or DOWN to change the value, and then press the CONFIRM button to save the settings.
Reset
Press the UP and DOWN buttons simultaneously and hold them for 3 seconds. Press the DOWN button twice, then press the CONFIRM
button to reset the device to the default settings. Press UP or DOWN to change the value, and then press the CONFIRM button to save the
settings.
Specifications
Temperature, units of measurement
Operating temperature range
Operating humidity range
Probe length, m
Power supply
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
The base station should be placed in a room within the manufacturer's recommended humidity and temperature ranges. Take the necessary
precautions when using the device with children or others who have not read or who do not fully understand these instructions. Do not try
to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service
center. Protect the device from sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use accessories
and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with
damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately. Children should use the
device under adult supervision only.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty
against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk
accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles
you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions
are met.
For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.
°C
–40... +120°C
0... 99%
1.5
AC/DC adapter 5V 1000mA
4

Publicidad

loading