Descargar Imprimir esta página

Kongskilde MultiCutter MCC GR250X Manual Operativo página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Technical specifications:
Granulator housing
Motor
Power
Nom. amperage
Fuse
Rotor
Piping
Transmission
Weight
Weight w/o motor
Surface treatment
Noise level
Installation and fitting:
When pipes are being fitted on the Granulator, a fixing collar with screws must be used to ensure that the
pipe can only be removed with the aid of tools. The Granulator must be bolted to a stable plate.
During installation and inspection of pipes and machine, the motor must be disconnected from the power
supply. This can be done by activating the switch.
Before starting the GR 250X, a one-metre pipe must be mounted on each side of the Granulator for safety
reasons.
Starting and stopping:
The motor should be fitted with a lockable safety switch to enable the Granulator to be started and
stopped separately without stopping the unit, which it is connected with.
Maintenance:
The manufacturer recommends the bearings and coupling carrier plate being renewed after max. 4800
hours of operation.
It is also recommended to grind the rotor knives and fixed blades on the same occasion.
See "Replacing spare parts".
Manual_GR250X_180123_EN
High-carbon steel.
3,00kW (4 HP) type M100
1400/2800 rpm.
3 Phase, 230-460V, 50-60 Hz.
6,30A
16 Amp.
Hard-metal blades.
Ø200-Ø400 mm.
Direct coupling
220 kg. (485 lbs)
195 kg. (430 lbs)
Powder lacquering
65 dB (A)
EN
2

Publicidad

loading