Descargar Imprimir esta página

Sotera 825P Manual De Instalación Y Operación página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

|
825P-850P DIGITAL PULSE OUTPUT METERS
Fluid Compatibility
The 825P & 850P Digital Meters will handle most pesticides,
automotive fluids (except gasoline), and mild acids. It is also
compatible with the following fluids**:
100 Surpass® EC
3.38EC Pursuit®
Aatrex 4L®
Abate 4E®
Agrotain®
Apron®
Assure II®
Atraz ine 4L
Banvel SFG®
Banvel®
Bicep®
Blazer®
Broadstrike®+
Broadstrike®+
Camix TM
Caustic Soda (50%)
Clarity®
Command®3ME
Conclude®
Conclude®xtra
Contour
Detail™
Diesel Exhaust Fluid (DEF)
Diesel Fuel
Doubleplay®
Dual II®
Dual®
Dual®
Eptam 7E®
Ethylene Glycol
Fallowmaster®
Flexstar®
Frontier®
Fultime®
Furadan®
Fusion®
Gramoxone Extra®
* Requires EPDM Seals.
**Trademark information on page 17.
The 825P & 850P Digital Meters are NOT compatible with very strong
acids or if fluid flash point is below 100°F (38°C). If in doubt about
compatibility of a specific fluid, contact supplier of fluid to check for
any adverse reactions to the following wetted materials:
Polypropylene Body
Fluorocarbon Seals
sotera.com
Gramoxone lnteon™
Guardsman®
Harness xtra®
Karate®
Laddock S-12®
Lasso Micro Tech®
Lumax TM
Manifest™
Marksman®
Maxim®
Methyl Parathion
Motor Oil
Nufos®
Oil.Adend®
Phosphoric Acid
Poast HC®
Poast Plus®
Poast®
Princep 4L®
Prowl®
Prowl®
Reflex®
Rezult®
Ridomil Gold®
Roundup®
Sodium Hydroxide (50%)
Squadron®
Storm®
Superboll®
Surpass®
Topnotch®
Touchdown®
Treflan®
Treflan™
Treflan™ HFP
Water
Stainless Steel Screws/Shaft
PPS Chamber
INSTALLATION AND OPERATION MANUAL
Installation
Use PTFE tape or thread compound on all threaded joints.
1.
Determine direction for fluid flow and point arrow on meter body
in that direction.
2.
Thread hose or pipe into ports until snug. Be careful not to cross
thread when starting threads.
Installation Hint
To prevent cross threading, turn the pipe / hose backwards
(counterclockwise) until you feel it engage threads, then tighten.
Changing Meter Readout Position
If it is necessary to change position of the meter readout,
follow these steps (Refer to exploded view).
1.
Unscrew meter cap (item 1, page 12). Use a strap type oil
filter wrench or 5" open jaw type wrench if too tight to
unscrew by hand.
2.
Insert a wide, flat-head screwdriver into the upper slot and
gently pry up electronics module (see Figure 1).
3.
Gently rotate electronics module to desired location.
4.
Press electronics module down into meter cover in the correct
orientation.
5.
Thread on meter cap until hand tight. To check tightness, there
should be approximately 1/16" gap between the cap and ridge
on outlet port (see Figure 3).
UPPER PRY SLOT
LOWER PRY SLOT
FIGURE 1
O-RING
FIGURE 2
1/16" GAP
APPROXIMATE GAP
WHEN TIGHT
NOTE: If cap is not
sufficiently tight,
fluid can enter the
electronics and cause
permanent damage.
FIGURE 3
5

Publicidad

loading

Este manual también es adecuado para:

850p