Buffer tank connection
Outdoor
This is an application that connects the buffer tank to the Tank Unit.
Buffer tank's temperature is detected by buffer tank thermistor (specifi ed by Panasonic).
Without connection of Optional PCB, external pump can be used for circulation in the fl oor heating circuit.
Note : Buffer tank thermistor must be connected to main indoor PCB only.
Buffer tank + Solar
Outdoor
This is an application that connects the buffer tank to the Tank Unit before connecting to the solar water heater to heat up the tank.
Buffer tank's temperature is detected by buffer tank thermistor (specifi ed by Panasonic).
Solar panel's temperature is detected by solar thermistor (specifi ed by Panasonic).
Buffer tank shall use tank with built-in solar heat exchange coil independently.
During winter season, solar pump for circuit protection will be activated continuously. If does not want to activate the solar pump operation,
please use glycol and set the anti-freezing operation start temperature to -20°C.
Heat accumulation operates automatically by comparing the temperature of tank thermistor and solar thermistor.
This system requires Optional PCB (CZ-NS5P).
Note : Buffer tank thermistor must be connected to main indoor PCB only.
Boiler connection
Outdoor
This is an application that connects the boiler to the Tank Unit, to compensate for insuffi cient capacity by operate boiler when outdoor
temperature drops & heat pump capacity is insuffi cient.
Boiler is connected parallel with heat pump against heating circuit.
Besides that, an application that connects to the DHW tank's circuit to heat up tank 's hot water is also possible.
Boiler output can be control by either SG ready input from optional PCB or Auto control by 3 modes selection pattern.
(Operation setting of boiler shall be responsible by installer.)
This system requires Optional PCB (CZ-NS5P) for SG ready input control.
Depending on the settings of the boiler, it is recommended to install buffer tank as temperature of circulating water may get higher. ( It must
connect to buffer tank especially when select Advanced Parallel setting.)
Note : Buffer tank thermistor must be connected to main indoor PCB only.
Panasonic is NOT responsible for incorrect or unsafe situation of the boiler system.
Make sure the boiler and its integration in the system complies with applicable legislation.
Make sure the return water temperature from the heating circuit to the Tank Unit does NOT exceed 55°C.
Boiler is turned off by safety control when the water temperature of the heating circuit exceed 85°C.
16
Indoor
Buffer tank
Indoor
Buffer tank
Indoor
Buffer tank
Boiler
WARNING
CAUTION
Pump
Thermistor
Floor heating
Solar thermistor
Solar pump
Pump
Mixing valve
Thermistor
Floor heating
Mixing
Pump
Thermistor
valve
Floor heating
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - No
Buffer Tank connection - Yes
T for buffer tank
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - Yes
Buffer Tank connection - Yes
T for buffer tank
Solar connection - Yes
Buffer tank
T turn ON
T turn OFF
Antifreeze
Hi limit
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - Yes
Bivalent - Yes
Turn ON: outdoor temp.
Control pattern