7. care and maintenance
Disconnect the power cable from the pump before any maintenance and cleaning operation.
Use a soft, damp cloth to clean the plastic part. Do not use detergents, solvents or sharp objects.
Clean and store the pump in a frost-free location before the first frost strikes.
This symbol indicates that this product must not be disposed of with other household waste throughout the EU.
To avoid possible harm to the environment or human health caused by uncontrolled waste disposal, recycle
correctly to promote the sustainable reuse of material resources. To return your used device, please use the
return and collection systems or contact the store where the product was purchased. They can take this product
for environmental safe recycling.
8. troubleshooting
problem
The pump does not start
The pump has no flow
The pump does not stop
The flow is inadequate
The pump stops after
working for a short time
reason
- Power is not on
- The float switch is not connected to
the circuit
- The intake filter is clogged.
- The discharge pipe is clogged or bent.
- The float switch is locked at the top
and cannot sink.
- The intake filter is clogged..
- Decreased pumping capacity due to
dirty and abrasive water.
- The engine protection device stops
the pump because the water is too
dirty.
- The water is too hot. Thermal shut-
down stops the pump.
7
solution
- Check the mains voltage.
- Raise the float.
- Clean the intake filter with a jet of
water..
- Release the tube.
- Release the float and reposition the
pump on level ground.
- Clean the filter.
- Clean the pump and replace the worn
parts.
- Remove the mains plug. Remove
plug and clean pump and sump.
- Make sure the water temperature
does not exceed 35°C!