M
Tool holder arm release pedal
N
Carriage
O
Tool holder arm
P
Control console
V
Second speed switch
See fig.10.
Q
Turntable rotation control lever
R
Carriage movement control lever and
turntable holder arm
S
Turntable closing control
T
Turntable opening control
U
Mushroom headed push button for emer-
gency stopping
U
Start the machine with the main switch (A, Fig.
9) and make sure that the hydraulic power unit
motor is rotating in the direction indicated by
the arrow (A, Fig. 11) which can be seen on
the motor cap.
Otherwise, the rotation direction must be
corrected immediately in order not to damage
the pump unit.
46
T
S
R
Q
10
A
11
All machine parts are powered by low voltage
(24V), with the exception of the hydraulic power
unit and the turntable rotation motor, which
are powered with mains voltage.
WARNING
Make sure that all parts of the hydraulic cir-
cuit are tightened correctly. If pressurised oil
escapes, it can cause serious injury.
WARNING
The machine is equipped with devices that
guarantee the operator's safety:
1) Check valve on the turntable opening
line (located inside the swivel connector,
see Fig. 12A).
Prevent the wheel from falling due to acciden-
tal breakage of the oleodynamic circuit.
2) Dual seal, pilot-operated check valve (see
Fig.12B).
Prevent the turntable holder arm from falling
suddenly in the case of accidental breakage to
the oleodynamic circuit.
12B
WARNING
To prevent accidents when using the included
or optional accessories, make sure that the
mechanical parts have been correctly in-
stalled and well fixed to the parts.
When working, firmly grip the manual ac-
cessories.
NOTE.
The machine may also be used for tyre groov-
ing. Operate the turntable intermittently for
this operation.
- Operator's manual TBE 155
- E
nglIsh
12A