5.1.2 Standard operating panel
Stop
Pos. Symbol Description
1
Grundfos Eye: The indicator light shows the operating status of the product.
2
-
Light fields for indication of the setpoint.
3
Up/Down: The buttons change the setpoint.
Radio communication: The button enables radio communication with Grundfos GO Remote and other products of the
4
same type.
Start/Stop: Press the button to make the product ready for operation or to start and stop the product.Start: If you press the
button when the product is stopped, the product starts if no other functions with higher priority have been enabled.Stop: If
5
you press the button when the product is running, the product always stops. When you press the button, the stop icon
appears at the bottom of the display.
Related information
6.30 "Buttons on product" ("Enable/disable settings")
6.49 Priority of settings
5.1.2.1 Setting the setpoint in constant parameter mode
The following applies for motors set to operate in Const. other val.
Set the desired setpoint by pressing the Up or Down buttons.
The green light fields on the operating panel indicate the setpoint set.
The following example applies to a pump or motor in an application where a pressure sensor gives a feedback to the pump or motor. The
sensor has been set manually, and the pump or motor does not automatically register a connected sensor.
Light fields 5 and 6 are activated, indicating a desired setpoint of 3 bar with a sensor measuring range from 0 to 6 bar. The setting range is
equal to the sensor measuring range.
bar
6
3
0
Related information
6.5 "Control mode"
5.1.2.2 Setting the setpoint in constant curve mode
Set the desired setpoint by pressing the Up or Down buttons.
The green light fields on the operating panel indicate the setpoint set.
Example: In Constant curve mode, the motor output is between minimum and maximum speed defined by Operating range.
1