5.3 Grundfos Eye
The operating condition of the motor is indicated by Grundfos Eye on the motor operating panel.
Grundfos Eye indicator light
Indicator light
Indication
No lights are on.
Two opposite green indicator lights are rotating.
Two opposite green indicator lights are
permanently on.
One yellow indicator light is rotating.
One yellow indicator light is permanently on.
Two opposite red indicator lights are flashing
simultaneously.
38
A
Description
Power off
The motor is not running.
Power on
The motor is running. The indicator lights are rotating in the direction
of rotation of the motor when seen from the non-drive end.
Power on
The motor is not running.
Warning
The motor is running. The indicator light is rotating in the direction of
rotation of the motor when seen from the non-drive end.
Warning
The motor has stopped.
Alarm
The motor has stopped.