TRANSMITTER
Terminal board
+ -
Jumper e Dip Switch
E
N
G
S2
Distance
S5
Selection
(Jumper)
Supplying
S6
DIP 1
DIP 2
0
0
1
0
0
1
1
1
0
0
1
0
0
1
1
1
Trimmer
+
Supplying Positive 12V
-
Supplying Negative
It shows the presence of the supplyng
ON
1
2
3
4
RED
LED
S2
LED
ROSSO
Closed
Calibration (Red Led off)
Open
Normal working (Red Led on)
Closed
For distance between transmitter and receiver included between 35
and 100 meters.
Open
For distance between transmitter and receiver included between 5
and 35 meters
Closed
12 V
Supplying
Open
24 V
Supplying
DIP 3
DIP 4
(with open S5 )
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
or 24V
S6
RANGE
RANGE
(with closed S5 )
5
15
20
23
27
30
33
37
- +
RV1
- 20 -
(min.11,5 V
/ max 27,8 V
S5
For
adjustment of the
38 mt
beam signal it is also
55 mt
necessary to set the
68 mt
distance between
78 mt
receiv er
87 mt
transmitter by use of
96 mt
dip-switch.
105 mt
113 mt
Trimmer RV1 for trimming the
emitted signal.
It increases clockwise.