Do not throw away in the environment. 
 
 
During  disposal  of  the  pump,  please  comply 
rigorously  with  the  regulations  in  force  in  your  country, 
making sure that residues of the treated liquid are not left 
inside the pump. Most of pumps do not contain hazardous 
polluting material. 
Information  on  the  disposal  of  electric  and  electronic 
equipment  in  compliance  with  directive  2012/19/UE 
 
(RAEE). 
Warning: do not use the normal house trash bin to dispose 
of  this  product.  Used  electric  and  electronic  equipment 
must  be  handled  separately  and  in  compliance  with  the 
regulations  relating  to  the  treatment,  recovery  and 
recycling  of  the  said  products.  In  accordance  with  the 
regulations  applied  in  the  member  States,  private  users 
resident  in  the  EU  can  take  used  electric  and  electronic 
equipment free of charge to designated collection centers. 
If  you  experience  difficulties  in  locating  an  authorized 
disposal  center,  consult  the  dealer  from  whom  you 
purchased  the  product.  The  national  regulations  provide 
sanctions  against  whoever  unlawfully  disposes  of  or 
abandons waste of electric or electronic equipment. 
 
 
5
ELECTRICAL CONNECTION 
CAUTION! ALWAYS FOLLOW THE SAFETY REGULATIONS!
 
SPECIALIZED  PERSONNEL:  The  electrical  installation 
 
must  be  carried  out  by  skilled  electrician  who  assumes 
all the responsability. 
ELECTROMAGNETIC  COMPATIBILITY:  The  product 
has  been  tested  under  one  of  the  typical  conditions  of 
 
use in accordance with the EC Declaration of Conformity 
standards.  Experience  has  shown,  however,  that 
significant  variations  in  EMC  noise  levels  can  occur  by 
changing  the  length  of  the  cables  ,  their  section,  their 
location,  etc.  If  interference  with  other  equipment 
occurs, install noise reduction filters. 
 
Connection 
Follow the wiring diagram shown in "Annex A" Pic. 1. 
 
As  regards  electrical  connection,  please  refer  to  the 
inverter manual. 
 
Ensure  that  mains  voltage  and  frequency  match 
those  specified  in  the  inverter  manual  and  that  it  is 
possible to make a good earth connection. 
 
It  is  recommended  to  provide  a  specific  power  line 
for the connection of the system. 
Always  install  a  magnetothermal  residual  current 
 
device  with  a  sensitivity  of  0,03A  upstream  from  the 
inverter. 
The electrical installation must have a switch with at 
 
least a 3mm. opening between contacts. 
Provide the installation of a motor protection switch 
 
between the pump and the inverter. 
Switch off the power supply upstream of the system 
 
before performing the electrical wiring of the inverter and 
of the pump. 
 
The  electrical  connections  must  be  protect  against 
humidity.  If  there  is  any  risk  of  flooding,  the  connections 
must be moved to a protect area. 
 
Pump power cord 
 
The electropump is supplied with the power cord for 
 
the connection to the inverter. The connection is type "Y", 
according to regulation CEI EN 60335‐2‐41, therefore any 
damage  would  require  its  replacement  rather  than  its 
repair. 
In  case  of  damage  to  the  pump  cord,  it  should  be 
replaced  by  the  manufacturer,  its  technical  assistance 
service or a similarly qualified person, in order to prevent 
any risk. 
Where  it  is  necessary  to  extend  the  power  supply 
cord  of  the  pump,  it  should  be  checked  that  it  is  of  an 
appropriate  quality  and  section  compared  to  its  length 
and to the power of the motor (please, see "Annex X" Pic. 
2).  The cable length must be at least like the immersion 
depth  increased  by  + 3m.  The  connection must  be  made 
in a workmanlike manner by qualified personnel and with 
materials  ensuring  perfect  isolation  between  the 
conductors, tightness and waterproofness over time. 
Inverter power cord 
Check  that  the  cord  used  to  power  the  inverter  is  of  an 
appropriate quality and section compared to its length and 
to the power absorbed (please, see "Annex A", Pic. 2). 
Checking direction of rotation 
The  correct  direction  of  rotation  is  indicated  on  the  data 
plate of the pump near the the impeller location. 
 
6
INSTALLATION 
SKILLED  TECHNICAL  PERSONNEL:  The  installation 
must be carried out by skiled personnel in possession of 
the  technical  qualifications  required  by  the  specific 
legislation  in  force.  The  term  "skilled  personal"  means 
persons  whose  training,  experience  and  instruction,  as 
well as their knowledge of the respective standards and 
requirements  for  accident  prevention  and  working 
conditions, have been approved by the person in charge 
of  plant  safety,  authorizing  them  to  perform  all  the 
necessary  activities,  during  which  they  are  able  to 
recognize and avoid all dangers. (Definition IEC 364). 
Installation
Follow the assembly diagram shown in "Annex A" Pic. 
1. 
If  the  pump  is  installed  horizontally  (e.g.  in  a  tub)  it 
should be inserted into a cooling jacket. 
Before dunking the electropump in the well or tank, 
ensure that the place is free from sand or solid sediment. 
The pump must never be leaning against the bottom 
of  the  well.  To  prevent  this  situation,  hang  up  the  pump 
and run a cable through its upper handle. 
Introduce  into  the  delivery  pipe  an  expansion 
vessel, which is intended to compensate any leakage and 
to  prevent  continuous  stops/restarts  of  the  pump  that 
may lead to damages. 
The volume of the expansion vessel should be about 
10 % of the max. flow rate required (e.g. max. flow rate 
60  l/min,  use  a  vessel  of  at  least  6  l).  The  pre‐charge 
pressure should be around 1bar lower than the operating 
pressure  (e.g.  operating  pressure  3  bar,  pre‐charge 
pressure of the vessel 2 bar). 
Never  lift  or  transport  the  electropump  using  the 
power  cord  or  the  delivery  pipe.    Only  use  the  handle, 
applying a rope or a chain on it. Lift the electropump with 
suitable means according to its weight and size. 