1.3
TECHNICAL SPECIFICATIONS
MURELLE EQUIPE
Generators vers. MURELLE 35 BOX ErP.
Nominal heat output (80-60°C) (Pn max).
Nominal heat output (50-30°C) (Pn max).
Minimum heat output G20 (80-60°C) (Pn min).
Minimum heat output G20 (50-30°C) (Pn min).
Minimum heat output G31 (80-60°C) (Pn min).
Minimum heat output G31 (50-30°C) (Pn min).
Heat input (*)
Nominal.(Qn.max.-.Qnw.max).
Minimum.G20/G31.(Qn.min.-.Qnw.min).
Min/max operating yield (80-60°C).
Min/max operating yield (50-30°C).
Operating yield at 30% (40-30°C).
Losses after shutdown to 50°C (EN 15502).
Supply
voltage.
Adsorbed power consumption (Qn max).
Adsorbed power consumption (Qn min).
C.H. pump adsorbed power consumption.
Absorbed power.
Energy efficiency
Seasonal.energy.efficiency.class.of.the.heating.system.
Seasonal.energy.efficiency.of.the.heating.system.
Sound.power.of.the.heating.system........
Single module temperature regulation.
Water content modules.
Max operating pressure (PMS).
Max operating temperature (T max).
Exhaust temperature at nominal input (80-60°C).
Exhaust temperature at minimum input (80-60°C).
Exhaust temperature at nominal input (50-30°C).
Exhaust temperature at minimum input (50-30°C).
Minimun/Maximum exhaust capacity.
CO
at input minimum/maximum (G20).
2
CO
at input minimum/maximum (G31).
2
NOx measured (EN 15502-1:2015).
Maximum pressure exhaust manifold output
PIN number.
Category.
Type.
NOx class (EN 15502-1:2015).
Weight when empty.
Gas and nozzle pressure
Number.of.nozzles.
Nozzle.diversified.diameter.(G20).
Nozzle.diversified.diameter.(G31).
Consumption.at.nominal.power.(G20).
Consumption.at.minimum.power.(G20).
Consumption.at.nominal.power.(G31).
Consumption.at.minimum.power.(G31).
Supply.pressure.(G20).
Supply.pressure.(G31).
(*).Heat.input.of.the.heating.system.measured.using.lower.heating.value.(LHV)
38
70 BOX ErP
n°.
2.
kW.
67.6.(2.x.33.8).
kW.
74,4.(2.x.37.2).
kW.
3.2.
kW.
3.7.
kW.
5.5.
kW.
6.4.
kW.
69.6.(2.x.34.8).
kW.
3.48./.6.0.
%.
92.0./.97.2.
%.
106.3./.106.8.
%.
108,7.
W.
332.(2.x.166).
V-Hz.
230-50.
W.
218.(2.x.109).
W.
70.
W.
90.(2.x.45).
.
IPX4D.
.
A.
%.
93.
dB.(A).
56.
°C.
20/80.
l.
5.3.(2.x.2.65).
bar.(kPa).
3,5.(343).
°C.
85.
°C.
80.
°C.
60.
°C.
45.
°C.
35.
g/s.
1.67./.32.78.
%.
8.4./.9.3.
%.
10.0./.10.2.
mg/kWh.
26.
Pa.
150.
.
1312CO5858.
.
II2H3P.
.
B23P-B53P
B23-B53
-
.
6.(‹.56.mg/kWh).
kg.
243.
n°.
2.
ø.
3.5./.4.0.
ø.
2.8/3.0.
m
3
/h.
7.36.(2.x.3.68).
m
3
/h.
0.39.
kg/h.
5.40.(2.x.2.70).
kg/h.
0.46.
mbar.(kPa).
20.(1,96).
mbar.(kPa).
37.(3,63).
105 BOX ErP
3.
101.4.(3.x.33.8).
111.6.(3.x.37.2).
3.2.
3.7.
5.5.
6.4.
104.4.(3.x.34.8).
3.48./.6.0.
92.0./.97.2.
106.3./.106.8.
108,7.
498.(3.x.166).
230-50.
327.(3.x.109).
74.
135.(3.x.45).
IPX4D.
A.
93.
---.
20/80.
7.95.(3.x.2.65).
3,5.(343).
85.
80.
60.
45.
35.
1.67./.49.17.
8.4./.9.3.
10.0./.10.2.
26.
150.
1312CO5858.
II2H3P.
B23P-B53P
B23-B53.
.
-
6.(‹.56.mg/kWh).
400.
2.
3.5./.4.0.
2.8/3.0.
11.04.(3.x.3.68).
0.39.
8.1.(3.x.2.70).
0.46.
20.(1,96).
37.(3,63).
MURELLE 35 BOX ErP
1
33.8
37.2
3.2
3.7
5.5
6.4
34.8
3.48./.6.0
92.0./.97.2
106.3./.106.8
108,7
166
230-50
109
66
45
IPX4D
A
93
54
20/80
2.65
3,5.(343)
85
80
60
45
35
1.67./.16.39
8.4./.9.3.
10.0./.10.2
26
150
1312CO5858
II2H3P
B23P-B53P
B23-B53
-
6.(‹.56.mg/kWh)
165
2
3.5./.4.0
2.8/3.0
3.68
0.39
2.70
0.46
20.(1,96)
37.(3,63)