4.
Open the globe valve fully to permit air to escape and prevent air pressure
build up in the air tank during the break-in period.
5.
Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.
6.
Run the compressor for 20 minutes. Make sure the globe valve is open and
there is minimal air pressure build-up in tank.
7.
Check all air line fittings and connections/piping for air leaks by applying a
soap solution. Correct if necessary. NOTE: Minor leaks can cause the air
compressor to overwork, resulting in premature breakdown or inadequate
performance.
8.
Check for excessive vibration. Readjust or shim air compressor feet, if
necessary.
9.
After 20 minutes, close the globe valve. The air receiver will fill to "cut-out"
pressure and the motor will stop.
Before Each Start-Up:
1.
Place On/Auto/Off lever to "Off".
2.
Close the globe valve.
3.
Attach hose and accessories.
Risk of unsafe operation. Firmly grasp air hose in hand when
installing or disconnecting to prevent hose whip.
Risk of unsafe operation. Do not use damaged or worn
accessories.
NOTE: A regulator MUST be installed when using accessories rated at less than
175 PSI.
NOTE: The hose or accessory will require a quick connect plug if the air outlet is
equipped with a quick connect socket.
Risk of Bursting. Too much air pressure causes a hazardous
risk of bursting. Check the manufacturer's maximum pressure
rating for air tools and accessories. The regulator outlet pressure must never
exceed the maximum pressure rating.
Risk of unsafe operation. Compressed air from the unit may
contain wa ter condensation and oil mist. Do not spray un fil-
tered air at an item that could be damaged by moisture. Some air tools and
accessories may require filtered air. Read the in struc tions for the air tools and
accessories.
How to Start
:
1.
Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build.
Motor will stop when tank pressure reaches "cut-out" pressure.
2.
When the tank pressure reaches "cut-out" pressure open the globe valve.
IMPORTANT: When using regulator and other accessories refer to the manufacturers
instructions.
If any unusual noise or vibration is noticed, stop the
compressor immediately and have it checked by a trained
service technician.
The compressor is ready for use.