Installation
Part-Nr
Thread
6903840
G5/8 (external
thread)
Optional accessories for both options
Part- Nr
Thread
6530922
M24x2 (internal thread) -G3/4A
(external thread)
6531940
M26x2 (external thread) -G3/4
(external thread)
2.8
Scope of delivery
WARNING
!
If parts are missing or damaged, do not start the Nitrox 200.
2.8.1
Nitrox 200 (wall option)
Nitrox 200
Wall bracket
Dräger X-am® 5000 with oxygen sensor for measuring up to
100 % oxygen (incl. gassing adapter and hose)
28
Connection
Breathing air supply to breathing air
connection (Fig.1, Pos.13)
Connection
Nitrox connection
(Fig.1, Pos.3)
Nitrox connection
(Fig.1, Pos.3)
2.8.2
Nitrox 200 (carrying case option)
Nitrox 200
Dräger X-am® 5000 with oxygen sensor for measuring up to
100 % oxygen (incl. gassing adapter and hose)
Intermediate piece G5/8 (internal thread)
Intermediate piece G3/4 (external thread)
O
hose 200 bar, G3/4 (internal thread) (2x)
2
Breathing air hose 200 bar, G5/8 (external threat), preassembled
on one side
NOTICE
i
i
The quick guide is provided in different languages.
It is recommended prior to the commissioning to affix the
desired languages in the cover of the carrying case using the
enclosed hook and fleece points or in immediate proximity to
the installed wall option using appropriate tools.
3
Installation
Installation of the Nitrox 200 (wall option)
CAUTION
!
Risk of injury and risk of material damage when using the
Nitrox 200 wall option without prior installation.
Risk of uncontrolled movement of the Nitrox 200 without fixed
installation.
Prior to its use, the Nitrox 200 must be firmly affixed at a
suitable location. Adhere to weight guidelines.
The Nitrox 200 must be firmly affixed at a suitable location over the
wall mounting (Fig.1, Pos.5) using 4 screws (not included in scope of
delivery). The weight (see "General technical data" on page 37) and
the pressure applied during use must be taken into consideration when
selecting the installation location and the size of the screws.