Note: If the unit still does not work, please contact the service center. Under no circumstance
should you disassemble the unit or repair it.
Cautionary Notes
1. The unit contains high-precision components. Therefore, avoid extreme temperatures,
humidity, and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it
from dust.
2. Clean the blood pressure monitor body and the cuff carefully with a slightly damp, soft cloth.
Do not wash the cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol
(gasoline) as cleaner.
3. Leaky batteries can damage the unit. Remove the batteries when the unit is not used for a long
time.
4. The unit should not be operated by children to avoid hazardous situations.
5. If the unit is stored near freezing, allow it to acclimate at room temperature before use.
6. For users diagnosed with common arrhythmia (atrial or ventricular premature beats or atrial
fibrillation), diabetes, poor circulation of blood, kidney problems, or for users suffered from
stroke, or for unconscious users, the device may have difficulty in determining the proper blood
pressure.
7. To stop operation at any time, press the on/off button and the air in the cuff will be rapidly
exhausted.
Specifications
Measurement Method
Measurement Range
Pressure Sensor
Accuracy
Inflation
Deflation
Memory capacity
Auto-shut-off
Operation Environment
Storage Environment
Power Source
Dimensions
Weight
Arm circumference
Limited users
K.B.
*Specifications are subject to change without notice.
Warranty
1. This product is guaranteed for 2 years from the date of acquisition and this guarantee is
effective only by presenting the RECEIPT OF PURCHASE stating the buyer's name, date of
purchase, name, and address of the distributor.
2.
Only defective products with manufacturing problems are covered by this guarantee. Devices
with malfunctioning problems caused by misuse or improper handling even if not intentionally,
are not covered by guarantee.
3. The guarantee covers the functioning of the monitor with the exception of the cuff because it is
a fragile piece and if handled improperly it can blow up or to be punctured, etc.
4. This guarantee does not cover damages by dropping down the device, direct exposition to high
humidity, water, battery leakage, and the batteries included in the device, repairs executed by
unauthorized person, violation of the device by the customer or by unauthorized person.
5. The guarantee does not cover the cost of round-trip transport for repair, the result or damage
caused by improper use of the device and other expenses not specified here.
: Oscillometric
: Pressure: 40~250 mmHg; Pulse: 40~199 beats/ minute
: Semi conductor
: Pressure: ± 3 mmHg; Pulse: ± 5% of reading
: Manual Inflation
: Automatic Pressure Release Valve
: 60 memories
: 1 minute after last button operation
: 10°C~40°C (50°F~104°F); 40%~85% RH max.
: -10°C~60°C (14°F~140°F); 10%~95% RH max.
: 3V DC, two R06 (AA) batteries
: 106 (L) X 110 (W) X 50 (H) mm
: 285 g (G.W) (w/o batteries)
: Adult: 24~36 cm (9,4"~14,2")
: Adult users
: Short time operation 2 minutes.
: Type BF
Device and cuff are designed to provide special protection
against electrical shocks.
16