11. Description
The Bypass accessory can be used to manually select
one of two sources of incoming air supplying the VMI®
unit. This accessory is compatible with the VMI® range
(except VMI® URBAN and VMI® PRO).
Source B must be a direct outdoor air inlet.
Source A can be either an air inlet from a solar air heater
or another source of heat or cold. The Bypass is not
considered as a heating or air conditioning system.
Thanks to this accessory, heat or cold can be obtained
from a specific source.
Users can only control the Bypass using the wireless
switch provided.
12. Operation
Users can change the Bypass position using the switch
provided. Two positions are available.
▪ Users can press on the red side of the switch to
connect source A to the Bypass in order to supply the
VMI® system (Hot or cold or secondary source).
▪ Users can press on the blue side of the switch to
connect source B to the Bypass in order to supply the
VMI® system (Direct outside air).
13. Switch power
The switch is self-powered and no battery is required.
When the user presses the switch, enough current is
generated to transmit the command to the Bypass.
14. Declaration of conformity
Ventilairsec declares that the Bypass complies with:
▪ Directive
2014/30/EU
compatibility
▪ Directive 2014/35/EU on low voltage electrical
equipment
▪ Directive 211/65/EU on restriction of the use of
hazardous substances in electrical and electronic
equipment
The main applicable requirements of RED directive
2014/53/EU
▪ EMC:
• ETSI EN 301 489‐3: 2019 V2.1.1 with standard
ETSI EN 301 489‐1: 2019 V2.2.3: Short-range
devices operating in the 9 kHz to 246 GHz
frequency range
• EN 55014-1 2017: Mains-powered devices
10
on
electromagnetic
• EN 55014‐2: 2015: Category 4 devices (F>15
MHz)
• EN 61000‐3‐2: 2006 / A1: 2009 / A2: 2009:
Limits for harmonic current emissions
• EN 61000‐3-3: 2013:
changes, voltage fluctuations and flicker in public
low-voltage supply systems, for equipment with
rated current inferior or equal to 16 A per phase
and not subject to conditional connection
▪ Radio frequency:
• EN 300220-2 V3.1.1
• EN 300328 V2.1.1
▪ EMF
• EN 62479 (2010)
▪ Low voltage:
• EN 60335-1:2012 + A11:2014 + A13:2017
The EC marking is placed on the product - year: 2022
Ventilairsec declares that the Bypass complies with
dielectric testing requirements.
Limitation of voltage

Publicidad

loading

Productos relacionados para VMI BYPASS SMART

Este manual también es adecuado para:

Bypass