5. Installation Diagram
Installation details of parking heater
control switch
the main
equipment
air inlet
M6 nut
connect the
fuel inlet pipe
fuel pump connector
pulse
fuel
pump
filter
6. Switch controller and Remote Control type
- English 002 -
Fuse Box Cover
insert fuse protector
anode(red)
cathode (brown)
air outlet
sealing gasket
Gasket
fix the hose clamp
exhaust pipe (combustion emission)
exhaust pipe
fuel tank
use this screw to fix the
fuel tank on the metal plate
of the vehicle.
6.1 LCD Panel Instructions(NO.1)
1. Key Function
Set →enter the set state, can adjust and set parameter.Change the working state.
Confirm →In the set state, confirm current set point, enter next parameter setting. In the Unset state,can
check the status.
→ In the set state ,up regulation set the parameter.
In the Unset state,up regulation set the operating temperature.
On-off →Short Press to turn on, status light is always.Long press 2 seconds to turn off, status light
is flickering .
→In the set state,down regulation set the parameter.In the Unset state,down regulation set the
operating temperature.
2. Match Code
In the Unset state,first press the up-regulation button, meanwhile
press the confirm button, keep more than 3 seconds.Enter the match code Interface, hows HFA-, press
the on button to send the remote code.After finishing the match code, then exit the interface. The machine
enter the turn on state. If match code failed, it will not enter the turn on state.
3. Set up parameter(press the set button to enter, the related icons in display screen will be light)
(1)Time setting
Up and down button adjust the parameter. Press the confirm button, in turn, sets
up hour, minute. Press confirm button enter next state.
(2)Timing on-off setting
Defaults to off, shows 1-oF.Press the up regulation button to open, show
1-on, enter.Press confirm button, in turn, set up the first group, turn on and off time. And the second
group.After finish the adjusting, press confirm button to enter to next step.
(3)Manage password input
Press the up and down regulation button. After showing the correct
value, press the confirm button to enter into next step. After inputting the correct 4 numbers, press the
confirm button to enter into next step.
(4)Pump capacity setting
Press the up and down regulation button, change the minimum pump
capacity. After achieve the demand value, press the confirm button to enter into next step.Maximum pump
capacity setting. Press the up and down regulation button to change it. After achieve the demand value,
press the confirm button to enter into next step.
(5)Fans' rotational speed setting
Press the up and down regulation button,change the minimum
speed. After achieve the demand value, press the confirm button to enter into next step.Maximum speed
setting. Press the up and down regulation button to change it. After achieve the demand value, press the
confirm button to enter into next step.
(6)Operating voltage setting
Only on the status is off, can choose the main board operating voltage,
press the up and down regulation button,choose switch voltage. The 12V system should change to show
U-12. The 24V system should change to show U-24.
(7)Speed signals setting
Press the up and down regulation button to set up speed signals. The
2 magnet polarity of vane wheel are opposite or there only 1 magnet, choose number 1. If the 2 magnet
polarity of vane wheel are same, choose number 2 . If choose wrong, will lead to speed with one time
difference.