EPT.19.REL.01/56858
Cable entries
The cable entries integrated in motor body, terminal box (motor side), capacitor box are part of this
certification.
All the other cable entries devices used on the enclosures are already properly IEC Ex certified.
The accessories used for cable entries and for unused holes must be subjected to a separate IEC Ex
certification according to the applicable standards IEC 60079-31 and IEC 60079-1 or IEC 60079-0.
Warning label
Special condition for a safe use
Supply voltage must be within:
±5% of the nominal value for temperature class T5;
±10% of the nominal value for temperature class T3 or T4.
IECEx Certificate of Conformity
page 3 of 3