5.1
VIDEO DOOR PHONE INSTALLATION
Use the screws and anchor bolts provided to fix the bracket. It is advisable to position the upper part of the
bracket at approximately 1.55 m (5.08 ft) from the ground.
There must be a minimum distance of 5 cm (1.97") between video door phone and the closest object.
5.2
TERMINALS DESCRIPTION
Arrange the duct so that it ends at the terminal board on the back of the video door phone.
-V +V
Power voltage input from dedicated power unit (respect the polarity)
L1 L2
Terminals for connecting video door phone to outdoor station
S1 S2
Terminals for connecting a second video door phone (Slave)
X1 X2
No-voltage contact for supplementary service actuation (Max switch
18
83 mm
3.27"
97 mm
3.81"
Extractable terminal board for facilitated wiring
REAR SIDE OF VIDEO DOOR PHONE
Video door phone coupling seats
1,55 m /
5.08 ft
1A @ 24V)
DS956-012C