5.3
SWITCHES SETTING
Two switches are provided on the back of the video door phone to configure the device as Master or Slave
and to adjust the pedestrian door opening time:
The door opener time must be configured on the Master video door phone.
Master/Slave
MASTER
SLAVE
(Default)
1 VIDEO DOOR PHONE
2 VIDEO DOOR PHONE
6
CALLING STATION INSTALLATION
DS956-012C
Pedestrian door opening time
Door opener contact
closing time: 3 sec
(Default)
MASTER
MASTER
Door opener contact
closing time: 6 sec
SLAVE
0.16"
Door opener contact
closing time: 300 ms
19