Set the high temperature limit stop (optional):
Turn the water off at the stops. Push the handle to the full up
position (1). Loosen the handle screw 4 complete turns with
a 4 mm allen wrench (2). Pull off the handle (3) and the nut
cover.
Turn the stem so that the handle screw faces forward.
Remove the handle screw (1). Pull off the high temperature
limit stop (2).
Reinstall the high temperature limit stop so that the pin on the
cartridge goes through the hole for the desired high tempera-
ture.
The temperatures shown on the illustration assume an incom-
ing cold water temperature of 50°F, and an incoming hot
water temperature of 140°F.
Test the faucet. If the high temperature is still too hot, reposi-
tion the high temperature limit stop.
Replace the nut cover (1). Replace the
handle screw and tighten it 4 complete
turns.
Replace the handle (1). Finish tightening the handle screw
(2). Install the screw cover (3)