Descargar Imprimir esta página

Deuba monzana MZGH4500 Manual De Instrucciones página 18

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
5.2 COMMISSIONING
Operation
1.
Open the valve on the gas cylinder by 1 ½ turns.
2.
Turn the rotary knob to the
Then press and hold the knob so that the gas flows
to the pilot burner and press the piezoelectric
igniter (A) at the same time.
The pilot burner is ignited after a 'click' sound. If
not, release the knobs and repeat the process
again after 30 seconds.
3.
Press and hold the knob for another 15 seconds to
activate the thermocouple after the pilot burner
has been lit. Now release the knobs completely.
Setting the heat levels
The radiant heater can be set to three different heat levels:
(LOW),
Press the knob lightly and turn it to the desired position.
Switching off
1.
Turn the rotary knob to the
2.
Turn off the gas supply at the gas cylinder valve.
Notes
a)
The radiant heater must always be used in a ventilated room. Let in plenty of fresh air and
never close the doors and windows. This ensures efficient combustion and a pleasant
environment.
Heat levels
1
2
3
b)
The protective grating covering the ceramic tiles prevents people from touching the very hot
surfaces of the ceramic tiles. Do not remove the grating under any circumstances. The grating
is not enough to protect your children; never leave your child alone in the room. Do not
touch the safety devices and pilot burner under any circumstances.
c)
Carry out a leak test regularly. Turn off the gas supply if you smell gas and contact Customer
Service. Do not try to check for a gas leak if a fire has broken out.
d)
Specifications:
With oxygen deficiency safety system and anti-topple device
Gas consumption: 4.2 kW, 305 g/h
Gas hose: Certified gas hose according to applicable EN standard (50 mm recommended)
and in accordance with local regulations.
Gas regulator: Certified according to EN 12864 or EN 16129 and in compliance with local
regulations (flow rate max. 1.5 kg/h).
The gas regulator's outlet pressure must be suitable for use and comply with the pressure
limits specified in the technical data below.
position (pilot light).
(MEDIUM)
and
position (pilot light).
Room size
30 m²
58 m²
84 m²
18
(HIGH).
Fresh air supply cross-
section
> 38 cm
2
> 73 cm
2
> 106 cm
2
www.DEUBAXXL.de

Publicidad

loading

Este manual también es adecuado para:

109364