Descargar Imprimir esta página

Deuba monzana MZGH4500 Manual De Instrucciones página 20

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
7.0 TROUBLESHOOTING
Problem
The pilot light is not
burning
The burner does
not ignite
After
a
certain
period of operation,
the radiant heater
switches off.
You can smell gas
8.0 TECHNICAL DATA
Item number
Model
PIN CODE CE
Nominal heat load
Gas type
Gas cylinder
Gas consumption
Ignition
Oxygen deficiency system
The oxygen deficiency system (ODS) switches off the gas supply if the CO
room rises to about 1.0%. Only use a suitable pressure regulator that corresponds to the heater's
technical data.
Destination countries
AT-DE-CH-SK
FR-GB-IE-PT
BE-CH-ES GR- IT-PT
CY-CZ-DK-EE-FI-GR-IT-LT-LV MT-
NL-NO-SE SI-SK-BG-RO-TR
PL
Possible causes
The gas cylinder is empty
The
nozzle
is
dirty
clogged.
The
ignition
device
defective
The gas cylinder is empty
The nozzle is clogged.
The
oxygen
deficiency
system (ODS) has responded.
The gas cylinder is empty.
Loose connection, leakage
109364
MZGH4500
2531DN-0034
4.2 kW
Propane (G31), butane (G30) or propane/butane mixtures
5 kg – 13 kg
305 g/h (4.2 kW) max.
Piezo ignition
ODS
Category
I3B/P
I3B
I3+
I3B/P
I3B/P
Solution
Replace the gas cylinder.
or
Contact Customer Service
is
Contact Customer Service
Replace the gas cylinder.
Contact Customer Service
Supply sufficient fresh air and wait a
few minutes before restarting the
appliance. If this does not solve the
problem, either the room volume or
the ventilation is insufficient.
Replace the gas cylinder.
Carry out a leak test on all gas-
carrying
parts,
connections; if defective, contact
Customer Service
P (mbar)
Gas
50
G30/G31
28–30
G30
28–30 / 37
G30/G31
28–30
G30/G31
37
G30/G31
20
tighten
loose
concentration in the
2
Nozzle
(1/100)
50/70
59/79
59/79
59/79
55/77
www.DEUBAXXL.de

Publicidad

loading

Este manual también es adecuado para:

109364