Technical Data
Maximum angle
Measuring range
Measurement accuracy
Electrical connection
Degree of protection
Degree of pollution
Height
Ambient humidity
Temperatures
Storage temperature
Environmental temperature
Operational temperature
+/- 4°
0.1-15 m
+/- 5 mm
18-30 VDC
1.8 W
0.1 A
max
Note: Power is supplied via a 100-240 V plug-in power supply unit (24 V
supply voltage) or via the PLC (24 V DC voltage SELV)
Protection against contact and moisture in accordance with IP 66
(EN 60529) and NEMA-4X/indoor (NEMA 250) if powercable or 0/4-20mA
cable is connected properly.
2
max. 2,000 m (ASL)
max. 95 %
-10 °C to +50 °C
-10 °C to +45 °C
Note: The sensor is not intended for outdoor use.
+1 °C to 45 °C
5