ENGLISH
Installation
N.B.
The appliance is not suitable for outdoor installation.
The appliance m ust be installed in accordance with current
safety regulations in the destination countr
instructions in this booklet. The appliance m ust be fitted to an
interior surface or wall of the dwelling that is structurally sound
enough to tak e its w eight (25 kg max. mod. 200, 38 kg max.
mod. 350).
Ensure that connections to the appliance are optimised and
simplified b y str ategic positioning of the junction bo
which the wires emerge (Fig.3).
Ceiling installation
Various mounting options are a vailable: Vortice recommends
fixing the appliance to the ceiling, using the special br
supplied (Fig.4).
In an y e vent, after mounting the appliance , chec k that it is
perfectly level in order to ensure f aultless operation. The ducts
used for conveying air must be of the correct siz e.
The ducts to and from the outdoors m
insulated and not subject to vibr ation.
The 125 mm (mod. 200) and 150 mm (mod.
diameter inlet and outlet pipes m
corresponding ports of the appliance by means of clips or other
suitable fastening systems.
If stale air is e
xhausted via the roof , the outlet m ust be
designed so as to prevent the formation of condensate and the
entry of rain water.
If fresh air enters via the roof , the intake must be designed so
as to prevent the formation of condensate and the entry of rain
water.
Condensate drain
During normal operation, condensate collects at the bottom of
the appliance in a double tray provided with two drain outlets.
The connection points are located on the bottom of the
appliance (Fig. 5). The condensate dr ain can be pro vided b y
connecting the dr ain outlets to tw o fle xible hoses with an
internal diameter of 19 mm appro x.
To avoid the f ormation of air b ubbles, create a siphon tr ap in
the hose connected to the outlet on the appliance denoted 1,
as illustrated in Fig. 5b.
Cut the end of the hose ob liquely.
N.B.
The siphon m ust be created obser
indicated in Fig.
5c; otherwise , correct oper ation of the
appliance cannot be guaranteed.
Condensate can also be dr
plumbing system of the building.
y, and with the
ust be ther mally
350) standard
ust be secured to the
ving the dimensions
ained off through the w
3 3
x, from
4 4
ackets
5 5
aste
1
2
29