Use
Appliance is automatically managed by an electronic control system. Appliance can automatically choose the most suitable
operating mode, depending on the outside temper ature.
When the appliance is switched on, both motors will r un at a really slo w speed for 3 minutes to allow repositioning of the
by-pass valve. After, motors will star t up again. NOTE: this is a nor mal system procedure and should not be perceiv ed as
a malfunction.
The appliance is wired to a special dedicated control panel, the functions of which are descr ibed further on.
This model can be used in combination with a Vortice preheater, which must be fitted and set up b y the installer.
The minimum distance of the preheater from the appliance is 500 mm.
"Heat recovery" Function
Fig. 3
This kind of function is nor mally actived, except when:
- automatic functions: "No-Frost", "By-Pass" and "Post-ventilation" are active;
- the manual function: "By-Pass MAN" is active.
Stale air (B) is expelled outside by means of an outside duct (D) while, at the same time, renewed air (A) is also extracted
from the outside. This renewed air is heated b y the combined action of the air/air heat e xchange. The renewed air enters
into the room by the Cleaned air duct (C).
"No-Frost" Function
The function is activable if 2 minutes are left after Appliance tur ning On.
"No-Frost" function is automatically active when the Appliance check a too low External air temperature, for a certain time.
When the function is active:
- the message "No-Frost" appears on the display;
- User can not change v entilation Speeds;
- "Program" function is NOT enabled.
The main scope of the "No-Frost" function is to avoid appliance damaging, because of too lo w temperatures.
When the message "Alar m!" and "Lock!" appears on the display: it rapresent a "no-frost timeout".
This means that "No-Frost" procedure has pro ved insufficient and the appliance goes into protected mode f or one hour ,
with the motors off, following which it will restar t automatically.
NOTE: Restarting is automatic and don' t need User presence.
"By-Pass" Function
Fig. 3
This type of operation is automatically set and it is usefull to ventilate the apartment without heat transfer. With the bypass
valve open, air can be e xtracted directly from inside (B), without passing through the heat e
introduced (C) air vented continues to pass through the heat e xchanger which will no longer be eff ective.
"By-Pass air Temperature" rapresent the "Desidered air temperature": according to this, the Appliance activates/deactivates
the bypass valve. User can select the "By-Pass air Temperature" into a range of temperatures:
from 15°C to 30°C. The preset "By-Pass air Temperature" value is 18°C (default).
NOTE: The "By-Pass" automatic function is deactivated when:
- External air temperature is less than 15°C;
- "No-Frost" function is active.
Example: Autumn case (sunny afternoon)
External air Temperature = 23°C;
Indoor air Temperature = 20°C;
Bypass air Temperature = 24°C.
Appliance e xtracts the Exter nal air (hot) without heat e
environmental conditions, a "free heating" is provided.
Example: Spring case (morning)
External air Temperature = 16°C;
Indoor air Temperature = 20°C;
Bypass air Temperature = 18°C.
Appliance e xtracts the Exter nal air (cold) without heat e
environmental conditions, a "free cooling" is provided.
34
xchanging with the Indoor air (cold).
xchanging with the Indoor air (hot).
xchanger. The flo w of the
In this w ay, thanks to
In this w ay, thanks to